Uncertainty Assessment for Determining the Discharge Coefficient C for a Multi-Opening Orifice

preprint OA: closed CC-BY-4.0
🔓 Open OA copy View at publisher

Abstract

The article contains the results of experimental studies for a multi-opening orifice with substitute constriction factor of β = 0.5 (m = 0.25), mounted in a DN50 hydraulic measuring flume. Flow measurements were taken for a progressing turbulent flow within Reynolds numbers (Re = 4700...19500). Based on experimental data, flow characteristics as well as discharge coefficient C characteristics were determined. Relative expanded uncertainty of determining a discharge coefficient C was estimated within the changes of volume flow qv from 0.35 dm3/s to 0.68 dm3/s. The value does not exceed 1.25% within the changes of Reynolds numbers 9800 ≤ Re ≤ 19500.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-22T02:00:06.705733+00:00
License: CC-BY-4.0