Uncertainty Assessment for Determining the Discharge Coefficient C for a Multi-Opening Orifice
preprint
OA: closed
CC-BY-4.0
Abstract
The article contains the results of experimental studies for a multi-opening orifice with substitute constriction factor of β = 0.5 (m = 0.25), mounted in a DN50 hydraulic measuring flume. Flow measurements were taken for a progressing turbulent flow within Reynolds numbers (Re = 4700...19500). Based on experimental data, flow characteristics as well as discharge coefficient C characteristics were determined. Relative expanded uncertainty of determining a discharge coefficient C was estimated within the changes of volume flow qv from 0.35 dm3/s to 0.68 dm3/s. The value does not exceed 1.25% within the changes of Reynolds numbers 9800 ≤ Re ≤ 19500.