Background Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive neuromodulation intervention that has been investigated as a treatment for substance use disorder (SUD) and its co-occurring disorders. As the number of rTMS SUD clinical trials increase, the safety and tolerability profile should be assessed. In this systematic review, we investigate adverse events (AEs) of rTMS in individuals with SUD and factors that may influence their occurrence, including treatment status, and substance-use type. Methods We performed a systematic PubMed search to identify all controlled trials of rTMS in SUD published up to January 2025. Eligible studies were assessed, and safety information was extracted for analysis. Results A total of 141 controlled clinical trials with 4,299 participants were included in their active arms. rTMS trials recruited participants who were engaged in active substance use (37 studies), in the pre-treatment phase (61), in early recovery (18), or in sustained recovery (25). Twenty-two studies (15.60 %) explicitly reported no AEs adverse effects. Sixty-nine (48.94 %) studies reported only mild AEs adverse events, while only six studies (4.26%) reported moderate AEs adverse events. Thirty-five studies did not report safety-outcomes/AEs. As expected, participants reported mild and temporary AEs such as headaches, pain or discomfort under the coil, or dizziness. The most frequent side effects were headache (57 studies in active TMS vs. 32 in sham TMS), pain or discomfort at the stimulation site (34 vs. 20 studies), and dizziness (11 vs. 5 studies). These effects were generally temporary and did not require participants to stop treatment. Only nine studies reported serious side effects (7 studies in active TMS and 2 in sham TMS). Importantly, no seizures attributable to active rTMS were reported in these SUD samples. The other severe events included severe headache (5 studies), tinnitus (1), disorientation (1), and suicidal ideation (1). In total, 9 studies reported dropout due to adverse effects. Thirty-five studies (24.82%) did not report safety-outcomes/adverse-events. Conclusion Overall, rTMS in SUD samples is safe and well-tolerated regardless of recovery stage and substance. Most reported side effects were mild, self-limiting, and tolerable. This evidence supports the safety of rTMS as a potential stand-alone or adjunctive treatment for SUD. Highlights We reviewed 141 controlled rTMS trials with 4,299 SUD participants rTMS in SUDs is safe and well-tolerated No reports of rTMS-induced seizures among 4,299 participants Most side-effects were mild and transient (headache, scalp pain) Standardized reporting of side-effects and adverse events is needed
Full text 4,188 characters · extracted from oa-doi-fallback · 4 sections · click to expand

Abstract

Background Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive neuromodulation intervention that has been investigated as a treatment for substance use disorder (SUD) and its co-occurring disorders. As the number of rTMS SUD clinical trials increase, the safety and tolerability profile should be assessed. In this systematic review, we investigate adverse events (AEs) of rTMS in individuals with SUD and factors that may influence their occurrence, including treatment status, and substance-use type.

Methods

We performed a systematic PubMed search to identify all controlled trials of rTMS in SUD published up to January 2025. Eligible studies were assessed, and safety information was extracted for analysis.

Results

A total of 141 controlled clinical trials with 4,299 participants were included in their active arms. rTMS trials recruited participants who were engaged in active substance use (37 studies), in the pre-treatment phase (61), in early recovery (18), or in sustained recovery (25). Twenty-two studies (15.60 %) explicitly reported no AEs adverse effects. Sixty-nine (48.94 %) studies reported only mild AEs adverse events, while only six studies (4.26%) reported moderate AEs adverse events. Thirty-five studies did not report safety-outcomes/AEs. As expected, participants reported mild and temporary AEs such as headaches, pain or discomfort under the coil, or dizziness. The most frequent side effects were headache (57 studies in active TMS vs. 32 in sham TMS), pain or discomfort at the stimulation site (34 vs. 20 studies), and dizziness (11 vs. 5 studies). These effects were generally temporary and did not require participants to stop treatment. Only nine studies reported serious side effects (7 studies in active TMS and 2 in sham TMS). Importantly, no seizures attributable to active rTMS were reported in these SUD samples. The other severe events included severe headache (5 studies), tinnitus (1), disorientation (1), and suicidal ideation (1). In total, 9 studies reported dropout due to adverse effects. Thirty-five studies (24.82%) did not report safety-outcomes/adverse-events.

Conclusion

Overall, rTMS in SUD samples is safe and well-tolerated regardless of recovery stage and substance. Most reported side effects were mild, self-limiting, and tolerable. This evidence supports the safety of rTMS as a potential stand-alone or adjunctive treatment for SUD. Highlights We reviewed 141 controlled rTMS trials with 4,299 SUD participants rTMS in SUDs is safe and well-tolerated No reports of rTMS-induced seizures among 4,299 participants Most side-effects were mild and transient (headache, scalp pain) Standardized reporting of side-effects and adverse events is needed Competing Interest Statement The authors have declared no competing interest. Funding Statement This study did not receive any funding Author Declarations I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained. Yes I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals. Yes I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance). Yes I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable. Yes Footnotes ↵+ These authors contributed as senior authors of this work. Data Availability All data produced in the present work are contained in the manuscript

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works