Development of an Optical Calorimeter Sensor for the Arc Thermal Performance Value (ATPV) Determination on Arc Rated Materials for Personal Protective Equipment
preprint
OA: closed
CC-BY-4.0
Abstract
The determination of the arc rating of arc resistant materials for the manufacture of personal protective clothing is conducted by measuring the incident and transmitted energies through calorimetry using thermocouples coupled to copper discs during the electric arc events. In this study, custom calorimeters were constructed incorporating both a thermocouple wire and an embedded optical fiber temperature sensor, and the arc ratings of different fabrics were determined in terms of arc thermal performance value (ATPV). The results revealed differences between measurements obtained with the two sensor types. Notably, the absence of electromagnetic interferences generated by the arc current and the enhanced time response achieved in the optical fiber temperature sensor signal led to an ATPV arc rating approximately 27% lower than that measured with the thermocouple. These findings underscore the importance of investigating the current methodology used for determine arc ratings, to ensure accurate measurement of incident and transmitted energy.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.
Source provenance
- europepmc
- last seen: 2026-05-20T01:45:00.602351+00:00
- unpaywall
- last seen: 2026-05-22T02:00:06.705733+00:00
License: CC-BY-4.0