Case studies of comprehensive gas control method during fully mechanized caving of low permeability ultra-thick coal seams

preprint OA: closed CC-BY-4.0
📄 Open PDF View at publisher

Abstract

Abstract Slicing fully mechanized caving mining now is a common high-efficiency mining method for ultra-thick coal seams. However, effective gas control has remained a difficulty in fully mechanized top-coal caving mining of low permeability ultra-thick coal seams. This study focused on mining of the #9-15 coal in Liuhuanggou Coal Mine, Xinjiang Province, China, and combined theoretical analyses and field test results for exploring comprehensive gas control methods for fully mechanized caving of low permeability ultra-thick coal seams. The No. (9-15)06 panel is a top slicing panel of the #9-15 coal with a mining height of 9 m, and the No. (4-5)02 goaf is located on the top of the panel. Through analysis, gas emissions in the No. (9-15)06 panel were mainly sourced from the coal wall, caving of top coal, goaf, and neighboring coal seams. A comprehensive gas control method based on source separation was proposed, which combined gas pre-drainage along the coal seam, high-position drilling on the top, pre-burial of pipes in the goaf, and pressure-balancing ventilation. Considering the poor gas pre-drainage effect for low permeability coal seams, the permeability of the coal seam was enhanced using hydraulic fracturing. According to coal seam and crustal stress distribution characteristics, the arrangement of the boreholes and backward segmented fracturing technology were designed. Field data show that coal underwent remarkable pre-fracturing under hydraulic fracturing. Mean gas pre-drainage from the boreholes was enhanced by nearly 4 times compared to the pre-hydraulic fracturing state. Finally, using the proposed comprehensive control method based on the gas sources, field tests were performed in the No. (9-15)06 panel. Field measurement data demonstrate that gas concentration in the return airflow fluctuated within a range of 0.05%~0.35%, i.e., gas concentration did not exceed the standard. The proposed gas control method can provide insightful reference for the other similar projects.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-22T02:00:06.705733+00:00
License: CC-BY-4.0