Predicting the Effect of Individual Weight-Bearing on Tibial Load and Fracture Healing after Tibial Plateau Fractures – Introduction of a Biomechanical Simulation Model | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Article Predicting the Effect of Individual Weight-Bearing on Tibial Load and Fracture Healing after Tibial Plateau Fractures – Introduction of a Biomechanical Simulation Model Annchristin Andres, Michael Roland, Kerstin Wickert, Stefan Diebels, and 2 more This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-6546928/v1 This work is licensed under a CC BY 4.0 License Status: Posted Version 1 posted You are reading this latest preprint version Abstract Purpose The prescribed amount of weight-bearing after tibial plateau fractures is controversial because it affects osteosynthetic construct stability and fracture healing. We aim to introduce a simulation model that adequately predicts the effects of different weight-bearing amounts on stability and healing, based on the patient’s individual fracture pattern and treatment construct. Methods To safely test different amounts of weight-bearing limits, we first extracted knee joint forces for different weight-bearing limits from musculoskeletal simulation based on monitoring data of 22 uninjured participants. Correct loading was ensured with a force-measuring insole. We then tested three patients after tibial plateau fracture with their current weight-bearing level and constructed a simulation model determining implant stress, knee joint force, and fracture gap interfragmentary strain. The patient-specific weight-bearing level was then substituted for weight-normalized uninjured participant data to test different weight-bearing levels in the simulation model. Results The simulation model calculated individual construct stiffness and interfragmentary strain at different weight-bearing levels following the clinical course. When comparing the patient's individual weight-bearing input with the weight-normalized input of the uninjured participants at the same level, comparable knee joint forces were extracted, showing the feasibility of this approach. Conclusion Using an adapted reference movement database, the model allows the determination of safe weight-bearing ranges concerning construct stability and fracture healing based on individual fracture morphology and treatment without exposing patients to excessive weight-bearing. Future studies can test this approach in more extensive patient-number studies and different treatment situations. Biological sciences/Computational biology and bioinformatics/Computational models Health sciences/Health care/Fracture repair Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 1 Introduction Tibial plateau fractures represent about 1% of all fractures in adults and are considered among the most complex joint injuries to be treated [ 18 , 21 ]. Resulting from high-energy mechanisms in younger patients, as well as low-energy trauma with associated poor bone quality in the elderly, this fracture entity is associated with a limited prognosis due to cartilage, as well as additional soft tissue injury [ 1 , 25 , 49 ]. While the specific osteosynthetic construct, depending on the fracture configuration, is still debated, the mainstay of treatment is open reduction and internal fixation [ 9 , 42 ]. According to the AO recommendations for weight-bearing after tibial plateau fracture treatment, patients should be kept non-weight-bearing for 10 to 12 weeks. However, a recent survey analysis among Dutch trauma surgeons has shown that this recommendation is only inconsistently followed by surgeons and that the prescribed start of at least some weight-bearing mostly ranges between 0 and 6 weeks [ 53 ]. Furthermore, the general compliance of patients to non- or limited weight-bearing regimens is limited in several studies [ 7 , 13 , 35 ]. Multiple studies have focused on determining a safe range for weight-bearing after these injuries, showing that at least a moderate amount of weight-bearing early on is not secure with standard open reduction internal fixation constructs, but might be beneficial for the patient regarding reported outcomes [ 1 , 9 , 32 , 34 , 55 ]. Studies have gone so far as to recommend permissive weight-bearing, according to the patient's comfort, but even then, patients reached full weight-bearing on average only after 14 weeks [ 34 ]. Depending on the fracture type and treatment, there is limited evidence that higher average joint reaction forces at the early point can lead to an increase in intraarticular step-off formation, thus showing the clinical need for a reliable tool to determine safe ranges of weight-bearing on an individual level [ 50 ]. To accurately determine the safe range of weight-bearing after tibial plateau fractures, musculoskeletal simulation can help assess individual construct stability. This is a reliable method to assess implant stresses, joint reaction forces, and interfragmentary fracture strain in other lower extremity fracture entities [ 5 , 40 ]. While standard models of the proximal tibia have already been constructed to test different mechanical conditions in fracture models [ 10 , 11 ], to our knowledge, no model has been developed to calculate individual, case-specific construct stability and the resulting interfragmentary strain. Previous research often relies on generic or population-averaged models that do not incorporate patient-specific anatomical data or individualized loading conditions [ 19 ]. These standard models typically apply simplified loading assumptions, uniform implant configurations, or generalized boundary conditions that may not accurately reflect the biomechanical environment of a healing fracture in a specific patient. The aim of the current study was thus to construct a simulation model that adequately predicts the effect of different weight-bearing amounts on the stability and interfragmentary strain of fracture treatment, based on the patient’s individual fracture pattern and treatment construct. 2 Materials and Methods This study recruited 22 healthy subjects, including 11 women and 11 men. We used the Xsens™ system, known for its precision in recording human movement, to capture motion data. The participants actively participated in the Timed Up and Go (TUG) test, a standardized assessment that measures their mobility and functional capacity [ 44 ]. During the TUG test, individuals had to rise from a seated position, walk a short distance, turn around, and return to the seated position, with the primary outcome being their completion time, measured in seconds. Before conducting the test, we provided all participants with a comprehensive explanation of the TUG procedure and its significance. We alternated the partial load conditions between subjects, with one group (n = 11) of 20 kilograms and the other group (n = 11) an equivalent load of half their body weight as partial weight bearing. To ensure participants adhered to their assigned partial weight, we actively employed a Moticon™ insole system to monitor and record the load during the TUG test. We actively instructed participants in properly handling crutches using the 3-point gait method to ensure consistency and safety. Furthermore, participants actively assessed their perception of the partial load using a household scale. Before the formal testing, all participants walked over the scale ten times to familiarize themselves with the sensation of the ordered partial load. We conducted the TUG test in two rounds: first, with a full load to establish reference values, and then with the arranged partial load, determined by the subject's group assignment (20 kg or half body weight). This dual-round approach allowed for a comprehensive evaluation of each participant's performance under full and partial load conditions, enabling an active comparison of their mobility and functional capacity in different load scenarios. The TUG test, a quick, reliable, and standardized assessment, actively evaluated participants' mobility and functional capacity throughout this study [ 31 , 37 ]. The workflow simultaneously measures the subject using the Xsens™ motion capturing system (Figure S1 ), Moticon™ measurement insoles (Figure S2), and Novel™ loadpads (Figure S3). The Xsens™ motion data is exported as .bvh (BioVision Hierarchy) files and imported into AnyBody™ software (Figure S4), a musculoskeletal simulation tool that works seamlessly with Xsens™. Data from the measurement insoles and loadpads are imported as .txt files into AnyBody™, where the musculoskeletal model is scaled to the subject's anthropometric data. This data is then used to calculate the joint and muscle forces inversely. The interface between Xsens™ and AnyBody™ ensures seamless data integration. Xsens™ gait data is exported as .bvh files for each subject and processed in AnyBody™ using the internal AMMR (AnyBody™ Model Repository), an open collection of examples and models of the musculoskeletal system, to map the gait cycle accurately. After completing the motion data acquisition with the 22 healthy subjects using the Xsens™ system, the data were analyzed using AnyBody™. Based on the recorded data, AnyBody™ allows us to perform a detailed analysis of joints, muscles, and moments. This analysis is critical for evaluating the effects of partial loads, particularly on knee forces, as part of our study of tibial plateau fractures (Fig. 1 ). The knee joint forces included for a controlled partial load (20 kg, or 50% of body weight) were derived from healthy individuals. Patient data were used to determine the force values for full weight-bearing. To allow for inter-subject comparison, all computed knee joint reaction forces from the AnyBody™ musculoskeletal model were normalized to each participant’s body weight (%BW). This was done by dividing the joint force values (in Newtons) by the individual’s body weight (in Newtons) and multiplying by 100. The resulting values are expressed as a percentage of body weight (%BW) and plotted across the gait cycle. The systems used for inertial motion capture (Xsens™), insole-based force measurement (Moticon™), and musculoskeletal modeling (AnyBody™) provide a validated and reproducible workflow, as demonstrated in previous studies [ 8 , 39 , 43 ]. Detailed instrumentation specifications are in the supplementary material. Furthermore, our research goes beyond healthy subjects as we actively measure actual patients with their prescribed partial weight-bearing. We follow a similar measurement workflow to healthy subjects and perform these measurements in the clinic using the Xsens™ motion measurement system. As with healthy subjects, the data obtained from the patients is also analyzed using AnyBody™ software. Figure 2 illustrates an example of knee joint force curves for a patient, using his motion-capturing data. Additionally, we utilize the patients’ CT images to generate patient-specific 3D models through segmentation and downstream image processing, which are then used in finite element (FE) simulations. This approach enables us to create a database of partial loads, providing insight into how various loads impact the patient’s musculoskeletal dynamics, with a particular focus on tibial plateau fractures and their treatment. The first step in the FE analysis methodology is to create geometric models using the individual DICOM image stack of the patient's postoperative CT scan and a six-rod bone density calibration phantom (QRM-BDC/6, QRM GmbH, Moehrendorf, Germany) [ 5 ]. Therefore, the images are segmented into masks using an adaptive thresholding procedure based on the calibration phantom. The calibration phantom with known density values establishes a relationship between Hounsfield Units and bone mineral density. After completing the segmentation, the treating trauma surgeon visually controlled the segmentation results of the fracture gap and made corrections if necessary. Then, we create high-resolution adaptive finite element meshes using the FE Mesher from ScanIP™ (ScanIP™, Synopsys, Mountain View, United States), employing C3D10 elements and defining node sets at the distal and proximal ends of the bone. Specify the homogeneous materials with standard properties within ScanIP™, sourcing values for the implant and fracture gap from the literature [ 14 , 33 ]. To establish the relationship between elasticity and bone density, map the grayscale values of the CT data to the Hounsfield scale and mechanical local bone properties [ 12 , 30 , 45 , 57 ]. The exact workflow is outlined in the supplementary material, including additional information about the mesh (Figure S5). Following previous studies, assume an isotropic heterogeneous material with a varying Young’s modulus and a fixed Poisson ratio [ 52 , 56 ]. Define cortical and trabecular bone mapping based on local ash density and equivalent mineral density, as described in prior research [ 5 , 23 , 36 ]. Pass all material properties to the FE meshes, storing them in the nodes and elements of the corresponding masks. After setting up node sets, elements, and material properties in ScanIP™, create the mesh and export it as a .inp file. Simulation Workflow Finite element analysis was conducted using Abaqus/CAE 2020, Abaqus™ (Dassault Systems, Velizy-Villacoublay, France). The input file generated in ScanIP™, which contained the finite element mesh, material properties, and predefined node sets (distal and proximal), was imported into the software. To simulate fixation, a displacement/rotation boundary condition was applied to the distal node set, fully constraining it in all three translational directions (U1, U2, and U3). Time-dependent knee joint forces derived from a musculoskeletal simulation in AnyBody™ were implemented in Abaqus using tabular amplitude definitions. Separate amplitude curves were created for each force component (Fx, Fy, and Fz). These forces were applied as concentrated loads to the proximal node set, each aligned with the corresponding spatial direction. Next, a static analysis step was defined with a time period matching that of the applied amplitudes. Nonlinear effects were disabled, and appropriate incrementation settings were selected to ensure stable convergence. For postprocessing, field output requests included the stress tensor (S), von Mises stress (MISES), strain tensor (E), displacement (U), reaction force (RF), and integration point volume (IVOL). Finally, a simulation job was created and submitted for execution. The simulation follows linear elastic assumptions. For the simulation of Interfragmentary movement, we focus on a mechanobiological approach based on mechanical stimuli, as discussed in the works of Claes and Heigele, and Shefelbine et al [ 17 , 48 ]. Specifically, we examine the interaction between octahedral shear strain, which is derived from the deviatoric component of the strain tensor related to shape distortion, and volumetric strain, which is associated with volume changes and hydrostatic pressure [ 27 ]. This approach emphasizes the significance of mechanical deviatoric strains in influencing cell differentiation and tissue formation. This notion aligns well with experimental findings [ 4 , 22 , 24 ]. To precisely analyze the mechanics within the fracture gap, we read the strain tensor for each tetrahedral element in that region. Both octahedral shear strain and volumetric strain were calculated and assessed according to the parameters established by Claes, Heigele, and Shefelbine et al [ 17 , 48 ]. A MATLAB script is used to convert ODB (Output Database) files, produced by Abaqus, to store simulation results, into VTK (Visualization Toolkit) files, enabling improved visualization and analysis through advanced post-processing tools. Further information about the simulation process can be found in the supplementary material. Case Data Use case 1 The first case is a 57-year-old healthy patient suffering from a closed proximal tibia fracture (AO/OTA 41 C1.2) after falling from a ladder. Initially treated at an external institution, the patient was introduced to our department with a posteromedial malreduction, resulting in an unreduced knee joint with posteromedial dislocation and with a bone non-union. The patient underwent revision with an open reduction and fixation using a medial, posteromedial, and anterolateral locking plate, along with a medial tricortical allograft. Postoperatively, a 20 kg partial weight-bearing order was given. The patient experienced an uneventful healing course, regaining full weight-bearing capacity and demonstrating timely fracture consolidation, with high satisfaction. Use case 2 The second case is of a 72-year-old patient with atrial fibrillation, hypertension, and hypothyroidism, who sustained a closed proximal tibia fracture in a fall from standing height (AO 41 B3.3h). She was treated with an open reduction and medial locking plate osteosynthetic fixation. Postoperatively, a 20 kg partial weight-bearing order was given. Initially, the patient exhibited delayed healing, with early screw-back failure at the 6-week follow-up. Upon further review of the history, while the patient attempted to comply with the weight-bearing recommendation, she reported difficulties maintaining balance, which may have contributed to an overload of the fracture situation. At this point, she was instructed to limit weight-bearing for another 6 weeks with only gradual increases under strict physical therapy guidance. The fracture then showed slow but steady consolidation over the next 6 months. The screw progressively backed out and was removed 3 months after the initial treatment. Use case 3 Case three is a 52-year-old healthy patient who sustained a closed proximal tibia fracture in a skiing accident (AO 41 C3.1e). She was treated with a medial, posteromedial, and anterolateral locking plate with an open reduction utilizing a lateral epicondylar osteotomy. Postoperatively, a 20 kg partial weight-bearing order was given. The patient exhibited an uneventful healing course, with timely fracture consolidation and a favorable clinical outcome. Accordingly, the simulation predicted an uneventful healing course during all weight-bearing levels. 3 Results This section first presents the results of the diagrams of the ground reaction forces during the TUG test, focusing on compliance with partial weight-bearing recommendations in healthy test subjects. The derived mean force curve of the knee joint, based on the analyzed AnyBody™ data, is then examined. This assessment facilitates a deeper understanding of the impact of partial weight-bearing on joint forces, and consequently, its influence on interfragmentary motion in patients. We then examine patient outcomes and the effects of different loading scenarios on design stiffness and interfragmentary motion. Here, the analysis focuses on the mechanical effects of different partial weight-bearing approaches and evaluates their effectiveness in promoting healing. This analysis contributes to a more nuanced understanding of the effectiveness of orthopedic treatments and bridges the gap between theoretical modeling and clinical application. Healthy Subjects A total of 22 participants underwent testing, comprising 11 women and 11 men. The average age of the participants was 26 ± 4 years. The mean weight is 71 ± 15 kg, and the average height is 176.5 ± 11 cm. The testing protocol involved each participant undergoing 11 walking trials with 50% of their body weight, followed by ten repetitions with a partial load of 20 kg. Figure 3 illustrates a representative instance of the ground reaction forces of the left and right feet obtained from insole measurements during sessions with healthy test subjects. The results of the mean knee joint forces, which were standardized to the body weight of the test subjects for comparison purposes, are illustrated in detail in Fig. 4 . It shows the mean knee joint force as a percentage of body weight during a gait cycle, initiated and completed by heel strike, with a partial load of 20 kg or 50% of the subjects' body weight. The testing commenced with recording the TUG task during normal walking (Fig. 4 A). Subsequently, the subject walked with crutches and underwent testing for partial weight-bearing using a household scale. The subject underwent repetitions of partial weight-bearing trials of 20kg on the right foot, consistent with standard clinical protocols (Fig. 4 B). Following these trials, the TUG task was repeated under the prescribed partial weight-bearing conditions, evaluating the ground reaction forces associated with this training regimen (Fig. 4 C). A more detailed representation of the knee joint forces can be seen in Figure S6. Therefore, partial weight-bearing was implemented in the AnyBody™ system, and inverse dynamics were performed to infer the respective joint forces. The implementation utilized the measured ground reaction force from Moticon™ in the gait model, along with the corresponding gait data from the Xsens™ measurement. This detailed analysis reveals the nuanced impact of partial load on knee joint forces. However, the differences between the test subjects, particularly at 50% of body weight, demonstrate the individual nature of the effects of partial loading on knee joint forces. An example is the stark contrast between the impact of 50 percent partial weight-bearing on subjects with a body weight of 50 kg and those with a body weight of 90 kg. Furthermore, it is crucial to recognize that a partial load of 20 kg can increase knee joint forces to a peak of 100% of a person's body weight, highlighting the significant impact that even relatively small external loads can have on knee joint biomechanical loads. Patients To investigate the effects of partial weight-bearing on different fracture scenarios and treatment modalities, digital twins representing the three patients were subjected to finite element simulation. These simulations replicate the biomechanical effects of various loading conditions on the patient's lower extremities, simulating a gait cycle with partial loading of 20 kg, 50% of the patient's body weight, and a full weight-bearing scenario. The methodology for applying these loads graphically, as shown in Fig. 1 , provides a clear visual reference for the biomechanical conditions applied. With the boundary conditions of the actual patient measurement, comparable results are obtained; however, these are limited by the variable testing of the partial load. Figure 5 presents the outcome of these simulations, with the data for the three patients arranged horizontally from use case 1 to 3. In particular, the analysis considers the stresses and strains in the fracture gap. It interprets these variables through the bone healing window [ 5 , 15 , 16 , 48 ] by linking local stresses and strains in the fracture gap (Fig. 5 D) - a concept that relates the mechanical environment of a fracture site to the potential for bone healing. Reducing interfragmentary motion at full weight-bearing improves fracture stability. Following the clinical course of uneventful healing, the simulation results for case #1 predicted an uneventful healing course after the revision of all weight-bearing levels. Case #2 exhibited high local stresses outside the defined healing window in the shear direction under full weight-bearing conditions, which was consistent with her postoperative behavior. Accordingly, limited fracture subsidence and backing out of a screw perpendicular to the fracture plane occurred. The course went on to fracture consolidation only after adaptation to her weight-bearing and physical therapy training. Accordingly, based on the clinical outcome of case #3, the simulation predicted an uneventful healing course at all weight-bearing levels. In addition, the simulation output von Mises stress analyzed stresses within the plate construction. In all three patient cases, the maximum von Mises stresses were below the material-specific yield strength of medical titanium aluminum alloys [Geetha et al., 2009], indicating sufficient construct stability. Case #1 showed a uniform stress distribution under all tested load conditions without significant stress concentrations. The maximum value is below 400 MPa, indicating increased stability when supplied with three plates. In case #2, the full load caused locally increased stresses (> 600 MPa) in the area of the distal screws of the medial plate. These stress maxima occurred close to the fracture plane, where high interfragmentary shear stresses were simultaneously measured. The clinically observed retraction of a screw correlates with this area and indicates a mechanically critical situation, which clinicians addressed by adjusting the post-treatment. In case #3, the stress values in all plates were consistently below 500 MPa. Here, too, the simulation showed stable behavior in all load scenarios. 4 Discussion The presented results demonstrate a simulation approach for determining a safe range of postoperative weight-bearing in individual patients after tibial plateau fractures, considering construct stability and interfragmentary strain that influence fracture healing. Notably, this model integrates the patient’s individual fracture and treatment situation with weight-adjusted movement norm data from a healthy group of participants, enabling the safe testing of different weight-bearing scenarios without exposing the patient to potentially harmful situations. Furthermore, construct stability is ensured for every patient by analyzing the von Mises stress, which remains below the critical material limits (i.e., yield strength of ~ 880 MPa) for titanium aluminum alloys used in medical-grade implants [ 26 ]. This guarantees that no threshold values are exceeded and the components are not subjected to excessive stress. In addition, the analysis shows that by increasing the number of implants, patients 1 and 3 had a mechanical stimulus in the lower part of the ranges expected for uneventful bone healing, indicating a favorable biomechanical environment for fracture healing. This improvement in stability is particularly beneficial for bone healing, as it reduces the mechanical stimulus at the fracture site and brings it into the optimal range of the healing window. The feasibility and validity of the presented simulation approach are grounded in a series of previous methodological and clinical studies that have established reliable workflows for biomechanical fracture simulation. Braun et al. [ 4 ] demonstrated the integration of motion capture in tibial pseudarthrosis treatment, introducing a patient-specific approach to assess fracture mechanics. Similarly, the automated CT-based finite element pipeline by Dahmen et al. [ 20 ] enabled individualized simulation of bone-implant constructs and laid the groundwork for reproducible, image-based simulation methods. These technical principles were further refined by Roland et al. [ 46 ], who proposed a direct algorithmic strategy for simulating bone healing based on CT imaging, and by Orth et al. [ 43 ], who used simulations to assess the effects of motion and weight-bearing on fracture healing in the lower leg. The current study extends these approaches by incorporating individualized musculoskeletal loading, derived from inertial motion capture and force-sensing insoles, and fracture-specific finite element modeling to create digital twins of postoperative patients. This enables the realistic simulation of weight-bearing scenarios without exposing patients to biomechanical risk, aligning with earlier feasibility studies that utilized dynamic in vivo load measurements and simulation-based analysis of fracture healing [ 5 , 6 ]. Concerning validation, the predictive power of the simulation model is supported by agreement with clinical outcomes in all three use cases, and notably, in case #2, simulation results under full weight-bearing conditions predicted localized overloading and interfragmentary shear strain outside the safe healing window, which corresponded to screw loosening and delayed consolidation observed in the clinical course. These findings are consistent with the mechanobiological principles of Claes and Heigele [ 14 , 17 ] and Shefelbine et al. [ 49 ], which establish threshold values for strain-driven tissue differentiation during bone healing. Moreover, recent experimental validation of interfragmentary motion in bone-implant systems, such as by Wickert et al. [ 55 ], reinforces the technical accuracy of the FEM-based predictions. In addition, the use of validated software environments (e.g., AnyBody™ and Abaqus™) and standardized imaging-to-simulation pipelines [ 12 , 24 , 45 , 57 ] further enhances the reproducibility and transferability of the approach. The current model builds upon and extends a robust methodological foundation, demonstrating technical feasibility and clinical validity in predicting mechanical outcomes relevant to postoperative fracture care. The recording of joint forces in healthy test subjects enables a differentiated understanding of the biomechanical effects of partial loading during walking. Detailed measurements of knee joint forces can be found in the OrthoLoad™ database [ 28 ]. Nine patients were measured using an instrumented knee joint implant while performing various activities. However, the database only provides two data sets, k5r and k2l, during a 3-point walk. This innovative approach circumvents the limitations associated with the need for measurable implants, giving valuable insights into the effects of loading during various walking scenarios. No commercially available intramedullary implants exist to determine the simulated parameters, making it impossible to validate the determined mechanical conditions experimentally. However, the general capability of fracture condition simulation has been previously demonstrated [ 27 ], and clinical validation through the healed fracture supports its efficacy. Furthermore, the application of a postoperative, simulated biomechanical healing control has been described in a case series and subsequently validated through animal experiments [ 20 , 46 ]. Additionally, research has shown that finite element simulations of bone-implant systems can be effectively validated using experimental data, reinforcing the accuracy of these simulations in replicating physical behaviors. Our recently published paper validated our simulation through biomechanical experiments on human specimens, and the results are consistent with those from the experiments [ 54 ]. In the aftercare of tibial plateau fractures, a primary focus with potential implications for the clinical and radiographic treatment outcomes is postoperative weight-bearing [ 1 , 9 , 50 , 55 ]. Traditionally, long periods of non-weight bearing have been prescribed for fear of secondary fracture dislocation, intraarticular step of formation, and, ultimately, a higher risk of posttraumatic arthritis. The current surveys, as well as clinical analysis, have shown, however, that these strict non-weight-bearing regimes are increasingly being abandoned in clinical practice, and that early, permissive weight-bearing in select cases is not associated with a higher degree of complications [ 1 , 50 ]. However, a low-powered study directly measuring postoperative joint subsidence through radio stereometrics analysis has shown that higher average knee joint loading during the stance phase of gait is not associated with increased postoperative fracture fragment migration beyond 3 mm [ 50 ]. The clinical significance of these increases in step-off formation, particularly in relation to long-term outcomes, remains unclear. The relevance of an individual simulation approach in determining this risk for secondary fracture migration and loss of reduction is evident in the second patient with medial-sided plating. This is the only patient simulated in this analysis with postoperative fracture subsidence and subsequent loosening of a screw in the plate apex, experiencing an outward pushing force running almost parallel to the fracture plane. This patient reported being permissively weight-bearing within the first weeks after the fracture and used no aids for walking, thus exposing her to at least her full body weight. Accordingly, the simulation of the case under full weight-bearing conditions showed the highest amount of fracture area, above safe ranges of interfragmentary motion according to the healing window [ 15 , 16 , 48 ], confirming the simulation's principal capability to assess situations at risk, already seen in studies [ 5 , 6 ]. Interestingly, the fracture in this patient consolidated in this position and has led to a satisfactory result for the patient after screw removal and prescription of partial weight-bearing for 6 weeks. The other simulated fracture situations with triple plate osteosynthesis have shown sufficient stability and safe ranges of interfragmentary motion throughout all weight-bearing levels. Accordingly, these fractures exhibited uneventful postoperative treatment courses, with no secondary dislocations or hardware failures. Both patients, however, required more than 8 weeks to gradually wean themselves off their walking aids. This aligns with current clinical studies and review analyses focusing on permissive weight-bearing. While it is safe to allow permissive weight-bearing, patients often require considerable time to regain full weight-bearing [ 34 ]. Simulation workflows, such as the one introduced here, can help identify patients who are safe for higher degrees of weight-bearing early during the treatment course and potentially increase their physical therapy training within their simulated safe range, guiding them toward earlier functional recovery [ 5 , 7 ]. The approach demonstrates the value of a simulation workflow in testing the weight-bearing associated effects on construct stability, joint reaction forces, and fracture healing. Identifying patients at risk for treatment failure early in the fracture course is a potentially significant factor in reducing the patient and socioeconomic burden of disease. On the patient's side, early interventions, ranging from adapting the aftercare regimen to surgical treatment, are possible. Aftercare adaptations can reduce weight-bearing in situations with increased interfragmentary motion or the risk of fixation failure. In contrast, the frequency and intensity of full weight-bearing can be addressed in understimulated situations. Furthermore, individual, simulation-adjusted adaptation of ROM braces could prevent certain critical motions. If the simulation determines that healing cannot be achieved by modulation of the weight-bearing input, the stiffness of the osteosynthetic construct could be adjusted, i.e., through augmentative plating, as well as further biologic measures (autologous bone graft) in mechanically sound situations without clinical healing. By establishing this simulation as a rehabilitation and screening tool, added socioeconomic effects can be expected through better healing rates through adapted therapy and earlier intervention in critical cases. Research on joint reaction forces in arthroplasty has shown that it is not only gait and associated weight-bearing that are putting stress on the proximal tibia, but also different movement situations that can exert high levels of force on a treated joint [ 3 ]. The presented workflow and the database of reference movements can be extended to include more scenarios, such as getting out of bed, walking at different speeds, or rising from a chair, to provide a more comprehensive simulation of individual patients’ movement patterns. Furthermore, this would allow us to test the particular patient in more detail and at a higher level of injury specificity, such as high-degree flexion testing in flexion-type injuries, to adapt postoperative range of motion protocols. Simulation approaches, such as the one introduced in this article, offer a unique opportunity to enhance our understanding of the effects of postoperative weight-bearing on osteosynthetic construct stability, fracture healing, and, ultimately, patient outcomes. Over the past 30 years, the discussion on potential weight-bearing recommendations following operative fracture treatment of the proximal tibia has remained active and controversial (Segal et al., 1993; Kubiak et al., 2013; Canton et al., 2022). Determining the biomechanical effects of weight-bearing on joint mechanics without computer simulation requires both controlled weight-bearing and precise radiographic measures of joint subsidence and fracture movement early during the fracture course. Limited patient number studies combining both these techniques have been performed showing that increased amounts of weight-bearing after proximal tibia fractures can be allowed without negative radiographic and clinical consequences [ 50 , 51 ], but to get to a comprehensive recommendation on all types of proximal tibia fractures, while considering the many treatment and hardware placement options is not feasible with these highly complex and research-oriented techniques. Clinical studies recommending permissive weight-bearing in these patients have shown that this can be associated with a decreased short-term recovery time, but also with limitations to the amount of weight-bearing, especially at the study endpoint, when the patient converts to a total knee arthroplasty [ 34 ]. To safely test these limitations early during the fracture treatment on the individual treatment situation, but safely with simulated, different weight-bearing levels, thus not only offers the opportunity to increase our understanding of safe boundaries during fracture rehabilitation but actually can allow for individualized aftercare concerning weight-bearing with wearable techniques, in situations that would otherwise be hard to assess and control [ 7 , 41 ]. The clinical feasibility of our approach has been demonstrated, and it can now be further refined in larger-scale clinical studies. The model's outcome predictions enable the development of tailored post-operative care plans, ensuring high-risk patients receive the necessary attention to prevent complications. Hospitals can allocate resources more efficiently, reducing healthcare costs by preventing complications and readmissions. Predictive insights enable clinicians to implement early intervention strategies, thereby improving patient outcomes. Additionally, the findings can inform enhanced recovery after surgery protocols, optimizing recovery times and reducing hospital stays. 5 Limitations While the study provides insightful results, it also offers opportunities for further research and refinement. Including a relatively small number of patients provides a focused initial investigation, paving the way for future studies with larger cohorts to enhance the robustness and applicability of the results. While the simulations do not capture the full biological context of the injury, including concomitant soft tissue damage and the effects of the ligamentous injury on joint stability, they open the door to more comprehensive modeling that incorporates these factors. In addition, the study highlights an important area for further investigation: determining the precise level of mechanical stimuli within the fracture zone that is optimal for healing. 6 Conclusion The introduced model enabled the construction of digital twins for our patients, allowing us to test the effect of different weight-bearing levels on individual construct stiffness, interfragmentary strain, and fracture healing following the clinical course. To safely test different weight-bearing scenarios early in the postoperative course, the model is adaptable to use weight and height-scaled joint reaction force input data from a reference database of healthy participants. Further adaptations of the simulation and validation in large-scale clinical studies are now possible to refine the model’s accuracy and predictive capability before its introduction into the clinic. Declarations 1 Conflict of Interest The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. 2 Author Contributions BB, MR, AA: Conceptualized the study, AA, MR, KW: Performed the simulations and the data analysis, BB, AA, MR: Analysis or interpretation of data and results, BB, TH: Interpretation of the results from a clinical perspective, clinical treatment and decision process, AA: Movement analysis, AA, MR, KW, SD: Interpretation of the results from an engineering perspective, SD, TH: Reviewed the manuscript, SD, BB, MR, TH: Secured funding of the study. All authors contributed to the manuscript and approved the final version. 3 Ethics Statement The studies involving humans were approved by the Institutional Ethics Committee of the University of Tuebingen (Project Number 318/2022BO2). All patients who can be identified via images or other information within the manuscript have given their consent. Informed and written consent was obtained from all healthy subjects. The healthy test subjects were also Saarland University members, making them suitable for experiments at the university. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study. All subjects and/or their legal guardian(s) have provided informed consent for the publication of identifying information and/or images in this online open-access publication. This consent was obtained in writing prior to submission and includes approval for the use of any personal or identifiable data presented herein. 4 Data availability The original contributions presented in the study are included in the article; further inquiries can be directed to the corresponding author. Researchers who wish to request access to data should send an email indicating the research purpose. Every request must be reviewed by the responsible institutional review boards, considering the risk of patient reidentification and compliance with the applicable data protection rules. 5 Funding This study was funded by the German Federal Ministry for Science and Education (BMBF) under the grant “VirtuS” (FKZ: 13GW0572). References Arnold, J. B. et al. Characteristics of postoperative weight bearing and management protocols for tibial plateau fractures: Findings from a scoping review. Injury 48, 12 (2017), 2634–2642. (2017). https://doi.org/10.1016/j.injury.2017.10.040 Peter Augat, M. W. et al. Biomechanical models: key considerations in study design. OTA Int. 4 (2021), 2. E099. https://doi.org/10.1097/OI9.0000000000000099 (2021). Bergmann, G. et al. and. Standardized loads acting in knee implants. PLoS One 9, 1 (2014). (2014). https://doi.org/10.1371/journal.pone.0086035 Ito, K., Bishop, N. E., Tami, I. & Schneider, E. In vivo comparison of early fracture healing under deviatoric and volumetric deformationsitle. Acta Bioeng Biomech 4, (2003), 754–5. (2003). Benedikt, J. et al. and Michael Roland. Individualized Determination of the Mechanical Fracture Environment After Tibial Exchange Nailing—A Simulation-Based Feasibility Study. Front. Surg. 8, September (2021), 1–9. (2021). https://doi.org/10.3389/fsurg.2021.749209 Benedikt, J. et al. An individualized simulation model based on continuous, independent, ground force measurements after intramedullary stabilization of a tibia fracture. Arch. Appl. Mech. 89, 11 (2019), 2351–2360. (2019). https://doi.org/10.1007/s00419-019-01582-5 Benedikt, J. et al. and Tim Pohlemann. Weight-bearing recommendations after operative fracture treatment—fact or fiction? Gait results with and feasibility of a dynamic, continuous pedobarography insole. Int. Orthop. 41, 8 (2017), 1507–1512. (2017). https://doi.org/10.1007/s00264-017-3481-7 Geoffrey, T., Burns, J. D., Zendler, Ronald, F. & Zernicke Validation of a wireless shoe insole for ground reaction force measurement. J. Sports Sci. 37, 10 (2019), 1129–1138. (2019). https://doi.org/10.1080/02640414.2018.1545515 Gianluca Canton, A., Sborgia, M., Dussi, N., Rasio & Murena, L. Early weight bearing in tibial plateau fractures treated with ORIF: a systematic review of literature. J. Orthop. Surg. Res. 17, 1 (2022), 1–8. (2022). https://doi.org/10.1186/s13018-022-03156-8 Ion Carrera, P. E. et al. An intact fibula may contribute to allow early weight bearing in surgically treated tibial plateau fractures. Knee Surgery, Sport. Traumatol. Arthrosc. 26, 3 (2018), 756–761. (2018). https://doi.org/10.1007/s00167-017-4428-7 Ion Carrera, P. E., Gelber, G., Chary, M. A., González-Ballester, J. C., Monllau & Jerome Noailly Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration. Int. Orthop. 40 (2016), 2163–2169. https://doi.org/10.1007/s00264-015-3106-y (2016). Cattaneo, P. M., Dalstra, M. & Frich, L. H. A three-dimensional finite element model from computed tomography data: A semi-automated method. Proc. Inst. Mech. Eng. Part H J. Eng. Med. 215, 2 (2001), 203–213. (2001). https://doi.org/10.1243/0954411011533760 Christopher, P. et al. Patient compliance with postoperative lower-extremity non-weight-bearing restrictions. J. Bone Jt. Surg. - Am. Vol . 98 (2016), 1563–1567. https://doi.org/10.2106/JBJS.15.01054 (2016). Claes, L. E. & Heigele, C. A. Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing. J. Biomech. 32, 3 (1999), 255–266. (1999). https://doi.org/10.1016/S0021-9290(98)00153-5 Lutz Claes. Improvement of clinical fracture healing – What can be learned from mechano-biological research? J. Biomech. 115, (2021), 110148. (2021). https://doi.org/10.1016/j.jbiomech.2020.110148 Lutz, E. C. Mechanobiology of Fracture Healing. From Basic Science to Clinical Application . (2017). Retrieved from https://link.springer.com/bookseries/10280 Lutz, E. et al. Effects of mechanical factors on the fracture healing process. Clin. Orthop. Relat. Res. 355, SUPPL. (1998). (1998). https://doi.org/10.1097/00003086-199810001-00015 Charles, M., Court-Brown & Caesar, B. Epidemiology of adult fractures: A review. Injury 37, 8 (2006), 691–697. (2006). https://doi.org/10.1016/j.injury.2006.04.130 Brian, P. et al. Fracture healing: A review of clinical, imaging and laboratory diagnostic options. Injury 48, (2017), S69–S75. (2017). https://doi.org/10.1016/j.injury.2017.04.020 Hannah, L. et al. Virtual Mechanical Testing Based on Low-Dose. J. Bone Jt. Surg. 101, 13 (2019), 1193–1202. (2019). https://doi.org/10.2106/JBJS.18.01139 Scott, L. et al. OpenSim: Open-source software to create and analyze dynamic simulations of movement. IEEE Trans. Biomed. Eng. 54 (2007), 1940–1950. https://doi.org/10.1109/TBME.2007.901024 (2007). Doblaré, M., García, J. M. & Gómez, M. J. Modelling bone tissue fracture and healing: A review. Eng. Fract. Mech. 71, 13–14 (2004), 1809–1840. (2004). https://doi.org/10.1016/j.engfracmech.2003.08.003 Edwards, W. B., Schnitzer, T. J. & Troy, K. L. Torsional stiffness and strength of the proximal tibia are better predicted by finite element models than DXA or QCT. J. Biomech. 46, 10 (2013), 1655–1662. (2013). https://doi.org/10.1016/j.jbiomech.2013.04.016 Richardson, J. B., Garcia, J. M., Kuiper, J. H. & Doblare, M. A numerical model to study the mechanical influences on bone fracture healing. Acta Bioeng Biomech 4, (2003), 394–5. (2003). Gaston, P., Will, E. M. & Keating, J. F. Recovery of knee function following fracture of the tibial plateau. J. Bone Jt. Surg. - Ser. B 87, 9 (2005), 1233–1236. (2005). https://doi.org/10.1302/0301-620X.87B9.16276 Geetha, M., Singh, A. K., Asokamani, R. & Gogia, A. K. Ti based biomaterials, the ultimate choice for orthopaedic implants - A review. Prog Mater. Sci. 54 (2009), 397–425. https://doi.org/10.1016/j.pmatsci.2008.06.004 (2009). Mohammad, S., Ghiasi, J., Chen, A., Vaziri, E. K. & Rodriguez and Ara Nazarian. Bone fracture healing in mechanobiological modeling: A review of principles and methods. Bone Reports 6, (2017), 87–100. (2017). https://doi.org/10.1016/j.bonr.2017.03.002 Bernd Heinlein, I. et al. and Georg Bergmann. ESB clinical biomechanics award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6–10 months. Clin. Biomech. 24, 4 (2009), 315–326. (2009). https://doi.org/10.1016/j.clinbiomech.2009.01.011 Benedikt Helgason, E., Perilli, E., Schileo, F., Taddei, S. & Brynjólfsson and Marco Viceconti. Mathematical relationships between bone density and mechanical properties: A literature review. Clin. Biomech. 23, 2 (2008), 135–146. (2008). https://doi.org/10.1016/j.clinbiomech.2007.08.024 Ivan Hvid, S. M., Bentzen, F., Linde, L., Mosekilde & Pongsoipetch, B. X-ray quantitative computed tomography: The relations to physical properties of proximal tibial trabecular bone specimens. J. Biomech. 22, 8–9 (1989), 837–844. (1989). https://doi.org/10.1016/0021-9290(89)90067-5 Nurul, I. I., Ahmad, M. S. & Zulfarina, M. S. Sharifah Nurul Aqilah Sayed Mohd Zaris, Zainal Abidin Nor Azlin, Isa Naina Mohamed, Norazlina Mohamed, Sabarul Afian Mokhtar, and Ahmad Nazrun Shuid. 2019. Physical function assessment of older adults with lower body fractures at 3 months post-discharge from hospital. Ther. Clin. Risk Manag . 15 , 201–210. https://doi.org/10.2147/TCRM.S189748 (2019). Efthymios Iliopoulos and Nikiforos Galanis. Physiotherapy after tibial plateau fracture fixation: A systematic review of the literature. SAGE Open Med. 8, (2020). (2020). https://doi.org/10.1177/2050312120965316 Imam, A. C. M.A., Fraker. Titanium Alloys as Implant Materials. Mater. Sci. (1996), 3–16. (1996). Kalmet, P. H. S. et al. and Martijn Poeze. Patient-reported quality of life and pain after permissive weight bearing in surgically treated trauma patients with tibial plateau fractures: a retrospective cohort study. Arch. Orthop. Trauma Surg. 139, 4 (2019), 483–488. (2019). https://doi.org/10.1007/s00402-018-3088-5 Kammerlander, C. et al. Inability of older adult patients with hip fracture to maintain postoperative weight-bearing restrictions. J. Bone Jt. Surg. - Am. Vol. 100, 11 (2018), 936–941. (2018). https://doi.org/10.2106/JBJS.17.01222 Nikolas, K., Knowles, J. M., Reeves & Ferreira, L. M. Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature. J. Exp. Orthop. 3, 1 (2016). (2016). https://doi.org/10.1186/s40634-016-0072-2 Morten, T., Kristensen, N. B. & Foss and Henrik Kehlet. Timed Up & Go Test as a Predictor of Falls Within 6 Months After Hip Fracture Surgery. 87, 1 (2007). (2007). Erik, N. et al. Early weight bearing after lower extremity fractures in adults. J. Am. Acad. Orthop. Surg. 21, 12 (2013), 727–738. (2013). https://doi.org/10.5435/JAAOS-21-12-727 Andersen, M. S., Damsgaard, M. & Rasmussen, J. Kinematic analysis of over-determinate biomechanical systems. Comput. Methods Biomech. Biomed. Engin. 12, 4 (2009), 371–384. (2009). Meir, T., Marmor, H., Dailey, R., Marcucio & Hunt, A. C. Biomedical research models in the science of fracture healing - Pitfalls & promises. Injury 51, 10 (2020), 2118–2128. (2020). https://doi.org/10.1016/j.injury.2020.06.025 Meir, T. et al. Use of Wearable Technology to Measure Activity in Orthopaedic Trauma Patients: A Systematic Review. Indian J. Orthop. 56, 7 (2022), 1112–1122. (2022). https://doi.org/10.1007/s43465-022-00629-0 Iain, R. et al. Surgical fixation methods for tibial plateau fractures. Cochrane Database Syst. Rev. 2015, 9 (2015). (2015). https://doi.org/10.1002/14651858.CD009679.pub2 Alvaro Muro-de-la-Herran. Begoña García-Zapirain, and Amaia Méndez-Zorrilla. 2014. Gait analysis methods: An overview of wearable and non-wearable systems, highlighting clinical applications. Sens. (Switzerland) . 14 (2), 3362–3394. https://doi.org/10.3390/s140203362 (2014). Podsiadlo, S. & Richardson, D. The Timed Up and Go: A Test of Basic Functional Mobility for Frail Elderly Persons. J. Am. Geriatr. Soc. 39, 2 (1991), 142–148. (1991). Rho, J. Y., Hobatho, M. C. & Ashman, R. B. Relations of mechanical properties to density and CT numbers in human bone. Med. Eng. Phys. 17 (1995), 347–355. https://doi.org/10.1016/1350-4533(95)97314-F (1995). Peter Schwarzenberg, K., Klein, S. J., Ferguson & Dailey, H. L. Brigitte von Rechenberg, Salim Darwiche, and Virtual mechanical tests out-perform morphometric measures for assessment of mechanical stability of fracture healing in vivo. J. Orthop. Res. 39, 4 (2021), 727–738. (2021). https://doi.org/10.1002/jor.24866 Whitelaw, G. P., Segal, D., Mallik, A. R., Wetzler, M. J. & Franchi, A. V. Early weight bearing of lateral tibial plateau fractures. Clin. Orthop. Relat. Res. (1993), Sep 1;294:232-7. (1993). Sandra, J., Shefelbine, P., Augat, L., Claes & Simon, U. Trabecular bone fracture healing simulation with finite element analysis and fuzzy logic. J. Biomech. 38, 12 (2005), 2440–2450. (2005). https://doi.org/10.1016/j.jbiomech.2004.10.019 Singleton, N., Sahakian, V. & Muir, D. Outcome after Tibial Plateau Fracture: How Important Is Restoration of Articular Congruity? J. Orthop. Trauma 31, 3 (2017), 158–163. (2017). https://doi.org/10.1097/BOT.0000000000000762 Dominic Thewlis, S. A., Callary, F., Fraysse & Solomon, L. B. Peak loading during walking is not associated with fracture migration following tibial plateau fracture: A preliminary case series. J. Orthop. Res. 33 (2015), 1398–1406. https://doi.org/10.1002/jor.22905 (2015). Dominic Thewlis, F. et al. Postoperative weight bearing and patient reported outcomes at one year following tibial plateau fractures. Injury 48, 7 (2017), 1650–1656. (2017). https://doi.org/10.1016/j.injury.2017.05.024 Nir Trabelsi, Z., Yosibash & Milgrom, C. Validation of subject-specific automated p-FE analysis of the proximal femur. J. Biomech. 42, 3 (2009), 234–241. (2009). https://doi.org/10.1016/j.jbiomech.2008.10.039 van der Vusse, M. et al. Is the AO guideline for postoperative treatment of tibial plateau fractures still decisive? A survey among orthopaedic surgeons and trauma surgeons in the Netherlands. Arch. Orthop. Trauma Surg. 137, 8 (2017), 1071–1075. (2017). https://doi.org/10.1007/s00402-017-2718-7 Kerstin Wickert, M. et al. and. Experimental and virtual testing of bone-implant systems equipped with the AO Fracture Monitor with regard to interfragmentary movement. Front. Bioeng. Biotechnol. 12, March (2024), 1–20. (2024). https://doi.org/10.3389/fbioe.2024.1370837 Williamson, M., Iliopoulos, E., Jain, A., Ebied, W. & Trompeter, A. Immediate weight bearing after plate fixation of fractures of the tibial plateau. Injury 49, 10 (2018), 1886–1890. (2018). https://doi.org/10.1016/j.injury.2018.06.039 Zohar Yosibash, R., Padan, L. & Joskowicz and Charles Milgrom. A CT-based high-order finite element analysis of the human proximal femur compared to in-vitro experiments. J. Biomech. Eng. 129, 3 (2007), 297–309. (2007). https://doi.org/10.1115/1.2720906 Cinzia Zannoni, R., Mantovani & Viceconti, M. Material properties assignment to finite element models of bone structures: A new method. Med. Eng. Phys. 20, 10 (1999), 735–740. (1999). https://doi.org/10.1016/S1350-4533(98)00081-2 Additional Declarations No competing interests reported. Supplementary Files SupplementaryMaterial.docx Cite Share Download PDF Status: Posted Version 1 posted You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-6546928","acceptedTermsAndConditions":true,"allowDirectSubmit":true,"archivedVersions":[],"articleType":"Article","associatedPublications":[],"authors":[{"id":459337364,"identity":"5fb88cff-4dbe-4192-ac1c-042e988ac18c","order_by":0,"name":"Annchristin Andres","email":"data:image/png;base64,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","orcid":"","institution":"Saarland University","correspondingAuthor":true,"prefix":"","firstName":"Annchristin","middleName":"","lastName":"Andres","suffix":""},{"id":459337365,"identity":"84be2ce7-de41-4070-b770-47f3d99f2674","order_by":1,"name":"Michael Roland","email":"","orcid":"","institution":"Saarland University","correspondingAuthor":false,"prefix":"","firstName":"Michael","middleName":"","lastName":"Roland","suffix":""},{"id":459337366,"identity":"3365d0e9-fd65-4061-a396-2c9f41856765","order_by":2,"name":"Kerstin Wickert","email":"","orcid":"","institution":"Saarland University","correspondingAuthor":false,"prefix":"","firstName":"Kerstin","middleName":"","lastName":"Wickert","suffix":""},{"id":459337367,"identity":"b6d8aae4-f5a1-44d3-8d73-f170f302e8cb","order_by":3,"name":"Stefan Diebels","email":"","orcid":"","institution":"Saarland University","correspondingAuthor":false,"prefix":"","firstName":"Stefan","middleName":"","lastName":"Diebels","suffix":""},{"id":459337368,"identity":"82e196a9-4b08-4047-ad88-d33d9e678585","order_by":4,"name":"Tina Histing","email":"","orcid":"","institution":"University Hospital Tuebingen on Behalf of the Eberhard-Karls-University Tuebingen, BG Hospital Tuebingen","correspondingAuthor":false,"prefix":"","firstName":"Tina","middleName":"","lastName":"Histing","suffix":""},{"id":459337369,"identity":"aa942b3f-37b1-46f0-8b83-8c0e4d61746c","order_by":5,"name":"Benedikt Braun","email":"","orcid":"","institution":"University Hospital Tuebingen on Behalf of the Eberhard-Karls-University Tuebingen, BG Hospital Tuebingen","correspondingAuthor":false,"prefix":"","firstName":"Benedikt","middleName":"","lastName":"Braun","suffix":""}],"badges":[],"createdAt":"2025-04-28 10:38:15","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-6546928/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-6546928/v1","draftVersion":[],"editorialEvents":[],"editorialNote":"","failedWorkflow":false,"files":[{"id":83279806,"identity":"9f5b4061-64d4-45ab-97cc-c18b65ab709f","added_by":"auto","created_at":"2025-05-22 10:05:45","extension":"png","order_by":1,"title":"Figure 1","display":"","copyAsset":false,"role":"figure","size":1430720,"visible":true,"origin":"","legend":"\u003cp\u003eIntegrating the Xsens™ motion capturing system with AnyBody\u003csup\u003eTM\u003c/sup\u003e uses input data from captured movements and the subsequent realistic boundary conditions to simulate knee joint reactions.\u003c/p\u003e","description":"","filename":"Fig1.png","url":"https://assets-eu.researchsquare.com/files/rs-6546928/v1/b047fd1440dcda8aa937422f.png"},{"id":83279805,"identity":"b53a43b7-b7a9-4bc2-8c3f-657ecbb2adfd","added_by":"auto","created_at":"2025-05-22 10:05:45","extension":"png","order_by":2,"title":"Figure 2","display":"","copyAsset":false,"role":"figure","size":815132,"visible":true,"origin":"","legend":"\u003cp\u003eKnee joint forces for full and partial weight-bearing in use case 3.\u003c/p\u003e","description":"","filename":"Figure2.png","url":"https://assets-eu.researchsquare.com/files/rs-6546928/v1/e2eeb4d9b00ce34208a606e4.png"},{"id":83279808,"identity":"9d2a2895-fbf5-4eed-be77-f4ff77753729","added_by":"auto","created_at":"2025-05-22 10:05:45","extension":"png","order_by":3,"title":"Figure 3","display":"","copyAsset":false,"role":"figure","size":1626558,"visible":true,"origin":"","legend":"\u003cp\u003eGround reaction force curves for (A) full weight-bearing, (B) Training with partial weight-bearing and crutches, and (C) partial weight-bearing reprehensive for one subject.\u003c/p\u003e","description":"","filename":"Fig3.png","url":"https://assets-eu.researchsquare.com/files/rs-6546928/v1/4e82d71655e1566d02e39b29.png"},{"id":83280709,"identity":"47f3a78b-6a14-4e88-b8de-288c65c0f39c","added_by":"auto","created_at":"2025-05-22 10:13:45","extension":"png","order_by":4,"title":"Figure 4","display":"","copyAsset":false,"role":"figure","size":621220,"visible":true,"origin":"","legend":"\u003cp\u003eMean knee joint force curve over all participants (n = 22) for (A) 20 kg weight-bearing, (B) 50 % body weight, and (C) full weight-bearing and natural walking.\u003c/p\u003e","description":"","filename":"Figure4.png","url":"https://assets-eu.researchsquare.com/files/rs-6546928/v1/630ff4a9debc820b1152c894.png"},{"id":83279832,"identity":"62bcf262-b071-47ec-8e37-d8568e03158b","added_by":"auto","created_at":"2025-05-22 10:05:45","extension":"png","order_by":5,"title":"Figure 5","display":"","copyAsset":false,"role":"figure","size":4908110,"visible":true,"origin":"","legend":"\u003cp\u003eResults of the biomechanical simulation of digital twins for use cases 1, 2, and 3 under three different loading conditions: (A) 20 kg partial weight-bearing, (B) 50% body weight, and (C) full weight-bearing. Additionally, the implant stress in MPa is included for the different loading conditions. (D) Color pattern of the healing window, illustrating the quantity and precise position of the elements in the various healing states, as described by Claes et al. [14].\u003c/p\u003e","description":"","filename":"Fig5.png","url":"https://assets-eu.researchsquare.com/files/rs-6546928/v1/deffc1df90ec9a795a3f0ec8.png"},{"id":84768080,"identity":"9f616488-ca41-48fc-9c13-67c4c7f92e3e","added_by":"auto","created_at":"2025-06-17 07:33:05","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":9885725,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-6546928/v1/88659daa-e22d-40d7-ae9a-780330b22841.pdf"},{"id":83281038,"identity":"a2e3100c-dd9c-4584-b2af-5ead0aa0f45e","added_by":"auto","created_at":"2025-05-22 10:21:45","extension":"docx","order_by":0,"title":"","display":"","copyAsset":false,"role":"supplement","size":4405769,"visible":true,"origin":"","legend":"","description":"","filename":"SupplementaryMaterial.docx","url":"https://assets-eu.researchsquare.com/files/rs-6546928/v1/827ace35eb1a91d9e299f681.docx"}],"financialInterests":"No competing interests reported.","formattedTitle":"Predicting the Effect of Individual Weight-Bearing on Tibial Load and Fracture Healing after Tibial Plateau Fractures – Introduction of a Biomechanical Simulation Model","fulltext":[{"header":"1 Introduction","content":"\u003cp\u003eTibial plateau fractures represent about 1% of all fractures in adults and are considered among the most complex joint injuries to be treated [\u003cspan citationid=\"CR18\" class=\"CitationRef\"\u003e18\u003c/span\u003e, \u003cspan citationid=\"CR21\" class=\"CitationRef\"\u003e21\u003c/span\u003e]. Resulting from high-energy mechanisms in younger patients, as well as low-energy trauma with associated poor bone quality in the elderly, this fracture entity is associated with a limited prognosis due to cartilage, as well as additional soft tissue injury [\u003cspan citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e, \u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e, \u003cspan citationid=\"CR49\" class=\"CitationRef\"\u003e49\u003c/span\u003e]. While the specific osteosynthetic construct, depending on the fracture configuration, is still debated, the mainstay of treatment is open reduction and internal fixation [\u003cspan citationid=\"CR9\" class=\"CitationRef\"\u003e9\u003c/span\u003e, \u003cspan citationid=\"CR42\" class=\"CitationRef\"\u003e42\u003c/span\u003e]. According to the AO recommendations for weight-bearing after tibial plateau fracture treatment, patients should be kept non-weight-bearing for 10 to 12 weeks. However, a recent survey analysis among Dutch trauma surgeons has shown that this recommendation is only inconsistently followed by surgeons and that the prescribed start of at least some weight-bearing mostly ranges between 0 and 6 weeks [\u003cspan citationid=\"CR53\" class=\"CitationRef\"\u003e53\u003c/span\u003e]. Furthermore, the general compliance of patients to non- or limited weight-bearing regimens is limited in several studies [\u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e, \u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e, \u003cspan citationid=\"CR35\" class=\"CitationRef\"\u003e35\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eMultiple studies have focused on determining a safe range for weight-bearing after these injuries, showing that at least a moderate amount of weight-bearing early on is not secure with standard open reduction internal fixation constructs, but might be beneficial for the patient regarding reported outcomes [\u003cspan citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e, \u003cspan citationid=\"CR9\" class=\"CitationRef\"\u003e9\u003c/span\u003e, \u003cspan citationid=\"CR32\" class=\"CitationRef\"\u003e32\u003c/span\u003e, \u003cspan citationid=\"CR34\" class=\"CitationRef\"\u003e34\u003c/span\u003e, \u003cspan citationid=\"CR55\" class=\"CitationRef\"\u003e55\u003c/span\u003e]. Studies have gone so far as to recommend permissive weight-bearing, according to the patient's comfort, but even then, patients reached full weight-bearing on average only after 14 weeks [\u003cspan citationid=\"CR34\" class=\"CitationRef\"\u003e34\u003c/span\u003e]. Depending on the fracture type and treatment, there is limited evidence that higher average joint reaction forces at the early point can lead to an increase in intraarticular step-off formation, thus showing the clinical need for a reliable tool to determine safe ranges of weight-bearing on an individual level [\u003cspan citationid=\"CR50\" class=\"CitationRef\"\u003e50\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eTo accurately determine the safe range of weight-bearing after tibial plateau fractures, musculoskeletal simulation can help assess individual construct stability. This is a reliable method to assess implant stresses, joint reaction forces, and interfragmentary fracture strain in other lower extremity fracture entities [\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e, \u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e]. While standard models of the proximal tibia have already been constructed to test different mechanical conditions in fracture models [\u003cspan citationid=\"CR10\" class=\"CitationRef\"\u003e10\u003c/span\u003e, \u003cspan citationid=\"CR11\" class=\"CitationRef\"\u003e11\u003c/span\u003e], to our knowledge, no model has been developed to calculate individual, case-specific construct stability and the resulting interfragmentary strain. Previous research often relies on generic or population-averaged models that do not incorporate patient-specific anatomical data or individualized loading conditions [\u003cspan citationid=\"CR19\" class=\"CitationRef\"\u003e19\u003c/span\u003e]. These standard models typically apply simplified loading assumptions, uniform implant configurations, or generalized boundary conditions that may not accurately reflect the biomechanical environment of a healing fracture in a specific patient.\u003c/p\u003e \u003cp\u003eThe aim of the current study was thus to construct a simulation model that adequately predicts the effect of different weight-bearing amounts on the stability and interfragmentary strain of fracture treatment, based on the patient\u0026rsquo;s individual fracture pattern and treatment construct.\u003c/p\u003e"},{"header":"2 Materials and Methods","content":"\u003cp\u003eThis study recruited 22 healthy subjects, including 11 women and 11 men. We used the Xsens\u0026trade; system, known for its precision in recording human movement, to capture motion data. The participants actively participated in the Timed Up and Go (TUG) test, a standardized assessment that measures their mobility and functional capacity [\u003cspan citationid=\"CR44\" class=\"CitationRef\"\u003e44\u003c/span\u003e]. During the TUG test, individuals had to rise from a seated position, walk a short distance, turn around, and return to the seated position, with the primary outcome being their completion time, measured in seconds. Before conducting the test, we provided all participants with a comprehensive explanation of the TUG procedure and its significance. We alternated the partial load conditions between subjects, with one group (n\u0026thinsp;=\u0026thinsp;11) of 20 kilograms and the other group (n\u0026thinsp;=\u0026thinsp;11) an equivalent load of half their body weight as partial weight bearing. To ensure participants adhered to their assigned partial weight, we actively employed a Moticon\u0026trade; insole system to monitor and record the load during the TUG test. We actively instructed participants in properly handling crutches using the 3-point gait method to ensure consistency and safety.\u003c/p\u003e \u003cp\u003eFurthermore, participants actively assessed their perception of the partial load using a household scale. Before the formal testing, all participants walked over the scale ten times to familiarize themselves with the sensation of the ordered partial load. We conducted the TUG test in two rounds: first, with a full load to establish reference values, and then with the arranged partial load, determined by the subject's group assignment (20 kg or half body weight). This dual-round approach allowed for a comprehensive evaluation of each participant's performance under full and partial load conditions, enabling an active comparison of their mobility and functional capacity in different load scenarios. The TUG test, a quick, reliable, and standardized assessment, actively evaluated participants' mobility and functional capacity throughout this study [\u003cspan citationid=\"CR31\" class=\"CitationRef\"\u003e31\u003c/span\u003e, \u003cspan citationid=\"CR37\" class=\"CitationRef\"\u003e37\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eThe workflow simultaneously measures the subject using the Xsens\u0026trade; motion capturing system (Figure \u003cspan refid=\"MOESM1\" class=\"InternalRef\"\u003eS1\u003c/span\u003e), Moticon\u0026trade; measurement insoles (Figure S2), and Novel\u0026trade; loadpads (Figure S3). The Xsens\u0026trade; motion data is exported as .bvh (BioVision Hierarchy) files and imported into AnyBody\u0026trade; software (Figure S4), a musculoskeletal simulation tool that works seamlessly with Xsens\u0026trade;. Data from the measurement insoles and loadpads are imported as .txt files into AnyBody\u0026trade;, where the musculoskeletal model is scaled to the subject's anthropometric data. This data is then used to calculate the joint and muscle forces inversely. The interface between Xsens\u0026trade; and AnyBody\u0026trade; ensures seamless data integration. Xsens\u0026trade; gait data is exported as .bvh files for each subject and processed in AnyBody\u0026trade; using the internal AMMR (AnyBody\u0026trade; Model Repository), an open collection of examples and models of the musculoskeletal system, to map the gait cycle accurately. After completing the motion data acquisition with the 22 healthy subjects using the Xsens\u0026trade; system, the data were analyzed using AnyBody\u0026trade;. Based on the recorded data, AnyBody\u0026trade; allows us to perform a detailed analysis of joints, muscles, and moments. This analysis is critical for evaluating the effects of partial loads, particularly on knee forces, as part of our study of tibial plateau fractures (Fig.\u0026nbsp;\u003cspan refid=\"Fig1\" class=\"InternalRef\"\u003e1\u003c/span\u003e). The knee joint forces included for a controlled partial load (20 kg, or 50% of body weight) were derived from healthy individuals. Patient data were used to determine the force values for full weight-bearing. To allow for inter-subject comparison, all computed knee joint reaction forces from the AnyBody\u0026trade; musculoskeletal model were normalized to each participant\u0026rsquo;s body weight (%BW). This was done by dividing the joint force values (in Newtons) by the individual\u0026rsquo;s body weight (in Newtons) and multiplying by 100. The resulting values are expressed as a percentage of body weight (%BW) and plotted across the gait cycle. The systems used for inertial motion capture (Xsens\u0026trade;), insole-based force measurement (Moticon\u0026trade;), and musculoskeletal modeling (AnyBody\u0026trade;) provide a validated and reproducible workflow, as demonstrated in previous studies [\u003cspan citationid=\"CR8\" class=\"CitationRef\"\u003e8\u003c/span\u003e, \u003cspan citationid=\"CR39\" class=\"CitationRef\"\u003e39\u003c/span\u003e, \u003cspan citationid=\"CR43\" class=\"CitationRef\"\u003e43\u003c/span\u003e]. Detailed instrumentation specifications are in the supplementary material.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eFurthermore, our research goes beyond healthy subjects as we actively measure actual patients with their prescribed partial weight-bearing. We follow a similar measurement workflow to healthy subjects and perform these measurements in the clinic using the Xsens\u0026trade; motion measurement system. As with healthy subjects, the data obtained from the patients is also analyzed using AnyBody\u0026trade; software. Figure\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003e illustrates an example of knee joint force curves for a patient, using his motion-capturing data. Additionally, we utilize the patients\u0026rsquo; CT images to generate patient-specific 3D models through segmentation and downstream image processing, which are then used in finite element (FE) simulations. This approach enables us to create a database of partial loads, providing insight into how various loads impact the patient\u0026rsquo;s musculoskeletal dynamics, with a particular focus on tibial plateau fractures and their treatment.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eThe first step in the FE analysis methodology is to create geometric models using the individual DICOM image stack of the patient's postoperative CT scan and a six-rod bone density calibration phantom (QRM-BDC/6, QRM GmbH, Moehrendorf, Germany) [\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e]. Therefore, the images are segmented into masks using an adaptive thresholding procedure based on the calibration phantom. The calibration phantom with known density values establishes a relationship between Hounsfield Units and bone mineral density. After completing the segmentation, the treating trauma surgeon visually controlled the segmentation results of the fracture gap and made corrections if necessary. Then, we create high-resolution adaptive finite element meshes using the FE Mesher from ScanIP\u0026trade; (ScanIP\u0026trade;, Synopsys, Mountain View, United States), employing C3D10 elements and defining node sets at the distal and proximal ends of the bone. Specify the homogeneous materials with standard properties within ScanIP\u0026trade;, sourcing values for the implant and fracture gap from the literature [\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e, \u003cspan citationid=\"CR33\" class=\"CitationRef\"\u003e33\u003c/span\u003e]. To establish the relationship between elasticity and bone density, map the grayscale values of the CT data to the Hounsfield scale and mechanical local bone properties [\u003cspan citationid=\"CR12\" class=\"CitationRef\"\u003e12\u003c/span\u003e, \u003cspan citationid=\"CR30\" class=\"CitationRef\"\u003e30\u003c/span\u003e, \u003cspan citationid=\"CR45\" class=\"CitationRef\"\u003e45\u003c/span\u003e, \u003cspan citationid=\"CR57\" class=\"CitationRef\"\u003e57\u003c/span\u003e]. The exact workflow is outlined in the supplementary material, including additional information about the mesh (Figure S5). Following previous studies, assume an isotropic heterogeneous material with a varying Young\u0026rsquo;s modulus and a fixed Poisson ratio [\u003cspan citationid=\"CR52\" class=\"CitationRef\"\u003e52\u003c/span\u003e, \u003cspan citationid=\"CR56\" class=\"CitationRef\"\u003e56\u003c/span\u003e]. Define cortical and trabecular bone mapping based on local ash density and equivalent mineral density, as described in prior research [\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e, \u003cspan citationid=\"CR23\" class=\"CitationRef\"\u003e23\u003c/span\u003e, \u003cspan citationid=\"CR36\" class=\"CitationRef\"\u003e36\u003c/span\u003e]. Pass all material properties to the FE meshes, storing them in the nodes and elements of the corresponding masks. After setting up node sets, elements, and material properties in ScanIP\u0026trade;, create the mesh and export it as a .inp file.\u003c/p\u003e \u003cp\u003eSimulation Workflow\u003c/p\u003e \u003cp\u003eFinite element analysis was conducted using Abaqus/CAE 2020, Abaqus\u0026trade; (Dassault Systems, Velizy-Villacoublay, France). The input file generated in ScanIP\u0026trade;, which contained the finite element mesh, material properties, and predefined node sets (distal and proximal), was imported into the software. To simulate fixation, a displacement/rotation boundary condition was applied to the distal node set, fully constraining it in all three translational directions (U1, U2, and U3). Time-dependent knee joint forces derived from a musculoskeletal simulation in AnyBody\u0026trade; were implemented in Abaqus using tabular amplitude definitions. Separate amplitude curves were created for each force component (Fx, Fy, and Fz). These forces were applied as concentrated loads to the proximal node set, each aligned with the corresponding spatial direction. Next, a static analysis step was defined with a time period matching that of the applied amplitudes. Nonlinear effects were disabled, and appropriate incrementation settings were selected to ensure stable convergence. For postprocessing, field output requests included the stress tensor (S), von Mises stress (MISES), strain tensor (E), displacement (U), reaction force (RF), and integration point volume (IVOL). Finally, a simulation job was created and submitted for execution. The simulation follows linear elastic assumptions.\u003c/p\u003e \u003cp\u003eFor the simulation of Interfragmentary movement, we focus on a mechanobiological approach based on mechanical stimuli, as discussed in the works of Claes and Heigele, and Shefelbine et al [\u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e, \u003cspan citationid=\"CR48\" class=\"CitationRef\"\u003e48\u003c/span\u003e]. Specifically, we examine the interaction between octahedral shear strain, which is derived from the deviatoric component of the strain tensor related to shape distortion, and volumetric strain, which is associated with volume changes and hydrostatic pressure [\u003cspan citationid=\"CR27\" class=\"CitationRef\"\u003e27\u003c/span\u003e]. This approach emphasizes the significance of mechanical deviatoric strains in influencing cell differentiation and tissue formation. This notion aligns well with experimental findings [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e, \u003cspan citationid=\"CR22\" class=\"CitationRef\"\u003e22\u003c/span\u003e, \u003cspan citationid=\"CR24\" class=\"CitationRef\"\u003e24\u003c/span\u003e]. To precisely analyze the mechanics within the fracture gap, we read the strain tensor for each tetrahedral element in that region. Both octahedral shear strain and volumetric strain were calculated and assessed according to the parameters established by Claes, Heigele, and Shefelbine et al [\u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e, \u003cspan citationid=\"CR48\" class=\"CitationRef\"\u003e48\u003c/span\u003e]. A MATLAB script is used to convert ODB (Output Database) files, produced by Abaqus, to store simulation results, into VTK (Visualization Toolkit) files, enabling improved visualization and analysis through advanced post-processing tools. Further information about the simulation process can be found in the supplementary material.\u003c/p\u003e \u003cp\u003eCase Data\u003c/p\u003e \u003cp\u003e \u003cb\u003eUse case 1\u003c/b\u003e \u003c/p\u003e \u003cp\u003eThe first case is a 57-year-old healthy patient suffering from a closed proximal tibia fracture (AO/OTA 41 C1.2) after falling from a ladder. Initially treated at an external institution, the patient was introduced to our department with a posteromedial malreduction, resulting in an unreduced knee joint with posteromedial dislocation and with a bone non-union. The patient underwent revision with an open reduction and fixation using a medial, posteromedial, and anterolateral locking plate, along with a medial tricortical allograft. Postoperatively, a 20 kg partial weight-bearing order was given. The patient experienced an uneventful healing course, regaining full weight-bearing capacity and demonstrating timely fracture consolidation, with high satisfaction.\u003c/p\u003e \u003cp\u003e \u003cb\u003eUse case 2\u003c/b\u003e \u003c/p\u003e \u003cp\u003eThe second case is of a 72-year-old patient with atrial fibrillation, hypertension, and hypothyroidism, who sustained a closed proximal tibia fracture in a fall from standing height (AO 41 B3.3h). She was treated with an open reduction and medial locking plate osteosynthetic fixation. Postoperatively, a 20 kg partial weight-bearing order was given. Initially, the patient exhibited delayed healing, with early screw-back failure at the 6-week follow-up. Upon further review of the history, while the patient attempted to comply with the weight-bearing recommendation, she reported difficulties maintaining balance, which may have contributed to an overload of the fracture situation. At this point, she was instructed to limit weight-bearing for another 6 weeks with only gradual increases under strict physical therapy guidance. The fracture then showed slow but steady consolidation over the next 6 months. The screw progressively backed out and was removed 3 months after the initial treatment.\u003c/p\u003e \u003cp\u003e \u003cb\u003eUse case 3\u003c/b\u003e \u003c/p\u003e \u003cp\u003eCase three is a 52-year-old healthy patient who sustained a closed proximal tibia fracture in a skiing accident (AO 41 C3.1e). She was treated with a medial, posteromedial, and anterolateral locking plate with an open reduction utilizing a lateral epicondylar osteotomy. Postoperatively, a 20 kg partial weight-bearing order was given. The patient exhibited an uneventful healing course, with timely fracture consolidation and a favorable clinical outcome. Accordingly, the simulation predicted an uneventful healing course during all weight-bearing levels.\u003c/p\u003e"},{"header":"3 Results","content":"\u003cp\u003eThis section first presents the results of the diagrams of the ground reaction forces during the TUG test, focusing on compliance with partial weight-bearing recommendations in healthy test subjects. The derived mean force curve of the knee joint, based on the analyzed AnyBody\u0026trade; data, is then examined. This assessment facilitates a deeper understanding of the impact of partial weight-bearing on joint forces, and consequently, its influence on interfragmentary motion in patients. We then examine patient outcomes and the effects of different loading scenarios on design stiffness and interfragmentary motion. Here, the analysis focuses on the mechanical effects of different partial weight-bearing approaches and evaluates their effectiveness in promoting healing. This analysis contributes to a more nuanced understanding of the effectiveness of orthopedic treatments and bridges the gap between theoretical modeling and clinical application.\u003c/p\u003e \u003cp\u003eHealthy Subjects\u003c/p\u003e \u003cp\u003e A total of 22 participants underwent testing, comprising 11 women and 11 men. The average age of the participants was 26\u0026thinsp;\u0026plusmn;\u0026thinsp;4 years. The mean weight is 71\u0026thinsp;\u0026plusmn;\u0026thinsp;15 kg, and the average height is 176.5\u0026thinsp;\u0026plusmn;\u0026thinsp;11 cm. The testing protocol involved each participant undergoing 11 walking trials with 50% of their body weight, followed by ten repetitions with a partial load of 20 kg. Figure\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e3\u003c/span\u003e illustrates a representative instance of the ground reaction forces of the left and right feet obtained from insole measurements during sessions with healthy test subjects. The results of the mean knee joint forces, which were standardized to the body weight of the test subjects for comparison purposes, are illustrated in detail in Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e4\u003c/span\u003e. It shows the mean knee joint force as a percentage of body weight during a gait cycle, initiated and completed by heel strike, with a partial load of 20 kg or 50% of the subjects' body weight. The testing commenced with recording the TUG task during normal walking (Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e4\u003c/span\u003eA). Subsequently, the subject walked with crutches and underwent testing for partial weight-bearing using a household scale. The subject underwent repetitions of partial weight-bearing trials of 20kg on the right foot, consistent with standard clinical protocols (Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e4\u003c/span\u003eB). Following these trials, the TUG task was repeated under the prescribed partial weight-bearing conditions, evaluating the ground reaction forces associated with this training regimen (Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e4\u003c/span\u003eC). A more detailed representation of the knee joint forces can be seen in Figure S6. Therefore, partial weight-bearing was implemented in the AnyBody\u0026trade; system, and inverse dynamics were performed to infer the respective joint forces. The implementation utilized the measured ground reaction force from Moticon\u0026trade; in the gait model, along with the corresponding gait data from the Xsens\u0026trade; measurement. This detailed analysis reveals the nuanced impact of partial load on knee joint forces. However, the differences between the test subjects, particularly at 50% of body weight, demonstrate the individual nature of the effects of partial loading on knee joint forces. An example is the stark contrast between the impact of 50 percent partial weight-bearing on subjects with a body weight of 50 kg and those with a body weight of 90 kg. Furthermore, it is crucial to recognize that a partial load of 20 kg can increase knee joint forces to a peak of 100% of a person's body weight, highlighting the significant impact that even relatively small external loads can have on knee joint biomechanical loads.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003ePatients\u003c/p\u003e \u003cp\u003eTo investigate the effects of partial weight-bearing on different fracture scenarios and treatment modalities, digital twins representing the three patients were subjected to finite element simulation. These simulations replicate the biomechanical effects of various loading conditions on the patient's lower extremities, simulating a gait cycle with partial loading of 20 kg, 50% of the patient's body weight, and a full weight-bearing scenario. The methodology for applying these loads graphically, as shown in Fig.\u0026nbsp;\u003cspan refid=\"Fig1\" class=\"InternalRef\"\u003e1\u003c/span\u003e, provides a clear visual reference for the biomechanical conditions applied. With the boundary conditions of the actual patient measurement, comparable results are obtained; however, these are limited by the variable testing of the partial load. Figure\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e5\u003c/span\u003e presents the outcome of these simulations, with the data for the three patients arranged horizontally from use case 1 to 3. In particular, the analysis considers the stresses and strains in the fracture gap. It interprets these variables through the bone healing window [\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e, \u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e, \u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e, \u003cspan citationid=\"CR48\" class=\"CitationRef\"\u003e48\u003c/span\u003e] by linking local stresses and strains in the fracture gap (Fig.\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e5\u003c/span\u003eD) - a concept that relates the mechanical environment of a fracture site to the potential for bone healing. Reducing interfragmentary motion at full weight-bearing improves fracture stability. Following the clinical course of uneventful healing, the simulation results for case #1 predicted an uneventful healing course after the revision of all weight-bearing levels. Case #2 exhibited high local stresses outside the defined healing window in the shear direction under full weight-bearing conditions, which was consistent with her postoperative behavior. Accordingly, limited fracture subsidence and backing out of a screw perpendicular to the fracture plane occurred. The course went on to fracture consolidation only after adaptation to her weight-bearing and physical therapy training. Accordingly, based on the clinical outcome of case #3, the simulation predicted an uneventful healing course at all weight-bearing levels.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eIn addition, the simulation output von Mises stress analyzed stresses within the plate construction. In all three patient cases, the maximum von Mises stresses were below the material-specific yield strength of medical titanium aluminum alloys [Geetha et al., 2009], indicating sufficient construct stability. Case #1 showed a uniform stress distribution under all tested load conditions without significant stress concentrations. The maximum value is below 400 MPa, indicating increased stability when supplied with three plates. In case #2, the full load caused locally increased stresses (\u0026gt;\u0026thinsp;600 MPa) in the area of the distal screws of the medial plate. These stress maxima occurred close to the fracture plane, where high interfragmentary shear stresses were simultaneously measured. The clinically observed retraction of a screw correlates with this area and indicates a mechanically critical situation, which clinicians addressed by adjusting the post-treatment. In case #3, the stress values in all plates were consistently below 500 MPa. Here, too, the simulation showed stable behavior in all load scenarios.\u003c/p\u003e"},{"header":"4 Discussion","content":"\u003cp\u003eThe presented results demonstrate a simulation approach for determining a safe range of postoperative weight-bearing in individual patients after tibial plateau fractures, considering construct stability and interfragmentary strain that influence fracture healing. Notably, this model integrates the patient\u0026rsquo;s individual fracture and treatment situation with weight-adjusted movement norm data from a healthy group of participants, enabling the safe testing of different weight-bearing scenarios without exposing the patient to potentially harmful situations. Furthermore, construct stability is ensured for every patient by analyzing the von Mises stress, which remains below the critical material limits (i.e., yield strength of ~\u0026thinsp;880 MPa) for titanium aluminum alloys used in medical-grade implants [\u003cspan citationid=\"CR26\" class=\"CitationRef\"\u003e26\u003c/span\u003e]. This guarantees that no threshold values are exceeded and the components are not subjected to excessive stress. In addition, the analysis shows that by increasing the number of implants, patients 1 and 3 had a mechanical stimulus in the lower part of the ranges expected for uneventful bone healing, indicating a favorable biomechanical environment for fracture healing. This improvement in stability is particularly beneficial for bone healing, as it reduces the mechanical stimulus at the fracture site and brings it into the optimal range of the healing window.\u003c/p\u003e \u003cp\u003eThe feasibility and validity of the presented simulation approach are grounded in a series of previous methodological and clinical studies that have established reliable workflows for biomechanical fracture simulation. Braun et al. [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e] demonstrated the integration of motion capture in tibial pseudarthrosis treatment, introducing a patient-specific approach to assess fracture mechanics. Similarly, the automated CT-based finite element pipeline by Dahmen et al. [\u003cspan citationid=\"CR20\" class=\"CitationRef\"\u003e20\u003c/span\u003e] enabled individualized simulation of bone-implant constructs and laid the groundwork for reproducible, image-based simulation methods. These technical principles were further refined by Roland et al. [\u003cspan citationid=\"CR46\" class=\"CitationRef\"\u003e46\u003c/span\u003e], who proposed a direct algorithmic strategy for simulating bone healing based on CT imaging, and by Orth et al. [\u003cspan citationid=\"CR43\" class=\"CitationRef\"\u003e43\u003c/span\u003e], who used simulations to assess the effects of motion and weight-bearing on fracture healing in the lower leg. The current study extends these approaches by incorporating individualized musculoskeletal loading, derived from inertial motion capture and force-sensing insoles, and fracture-specific finite element modeling to create digital twins of postoperative patients. This enables the realistic simulation of weight-bearing scenarios without exposing patients to biomechanical risk, aligning with earlier feasibility studies that utilized dynamic in vivo load measurements and simulation-based analysis of fracture healing [\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e, \u003cspan citationid=\"CR6\" class=\"CitationRef\"\u003e6\u003c/span\u003e]. Concerning validation, the predictive power of the simulation model is supported by agreement with clinical outcomes in all three use cases, and notably, in case #2, simulation results under full weight-bearing conditions predicted localized overloading and interfragmentary shear strain outside the safe healing window, which corresponded to screw loosening and delayed consolidation observed in the clinical course. These findings are consistent with the mechanobiological principles of Claes and Heigele [\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e, \u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e] and Shefelbine et al. [\u003cspan citationid=\"CR49\" class=\"CitationRef\"\u003e49\u003c/span\u003e], which establish threshold values for strain-driven tissue differentiation during bone healing. Moreover, recent experimental validation of interfragmentary motion in bone-implant systems, such as by Wickert et al. [\u003cspan citationid=\"CR55\" class=\"CitationRef\"\u003e55\u003c/span\u003e], reinforces the technical accuracy of the FEM-based predictions. In addition, the use of validated software environments (e.g., AnyBody\u0026trade; and Abaqus\u0026trade;) and standardized imaging-to-simulation pipelines [\u003cspan citationid=\"CR12\" class=\"CitationRef\"\u003e12\u003c/span\u003e, \u003cspan citationid=\"CR24\" class=\"CitationRef\"\u003e24\u003c/span\u003e, \u003cspan citationid=\"CR45\" class=\"CitationRef\"\u003e45\u003c/span\u003e, \u003cspan citationid=\"CR57\" class=\"CitationRef\"\u003e57\u003c/span\u003e] further enhances the reproducibility and transferability of the approach. The current model builds upon and extends a robust methodological foundation, demonstrating technical feasibility and clinical validity in predicting mechanical outcomes relevant to postoperative fracture care.\u003c/p\u003e \u003cp\u003eThe recording of joint forces in healthy test subjects enables a differentiated understanding of the biomechanical effects of partial loading during walking. Detailed measurements of knee joint forces can be found in the OrthoLoad\u0026trade; database [\u003cspan citationid=\"CR28\" class=\"CitationRef\"\u003e28\u003c/span\u003e]. Nine patients were measured using an instrumented knee joint implant while performing various activities. However, the database only provides two data sets, k5r and k2l, during a 3-point walk. This innovative approach circumvents the limitations associated with the need for measurable implants, giving valuable insights into the effects of loading during various walking scenarios.\u003c/p\u003e \u003cp\u003eNo commercially available intramedullary implants exist to determine the simulated parameters, making it impossible to validate the determined mechanical conditions experimentally. However, the general capability of fracture condition simulation has been previously demonstrated [\u003cspan citationid=\"CR27\" class=\"CitationRef\"\u003e27\u003c/span\u003e], and clinical validation through the healed fracture supports its efficacy. Furthermore, the application of a postoperative, simulated biomechanical healing control has been described in a case series and subsequently validated through animal experiments [\u003cspan citationid=\"CR20\" class=\"CitationRef\"\u003e20\u003c/span\u003e, \u003cspan citationid=\"CR46\" class=\"CitationRef\"\u003e46\u003c/span\u003e]. Additionally, research has shown that finite element simulations of bone-implant systems can be effectively validated using experimental data, reinforcing the accuracy of these simulations in replicating physical behaviors. Our recently published paper validated our simulation through biomechanical experiments on human specimens, and the results are consistent with those from the experiments [\u003cspan citationid=\"CR54\" class=\"CitationRef\"\u003e54\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eIn the aftercare of tibial plateau fractures, a primary focus with potential implications for the clinical and radiographic treatment outcomes is postoperative weight-bearing [\u003cspan citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e, \u003cspan citationid=\"CR9\" class=\"CitationRef\"\u003e9\u003c/span\u003e, \u003cspan citationid=\"CR50\" class=\"CitationRef\"\u003e50\u003c/span\u003e, \u003cspan citationid=\"CR55\" class=\"CitationRef\"\u003e55\u003c/span\u003e]. Traditionally, long periods of non-weight bearing have been prescribed for fear of secondary fracture dislocation, intraarticular step of formation, and, ultimately, a higher risk of posttraumatic arthritis. The current surveys, as well as clinical analysis, have shown, however, that these strict non-weight-bearing regimes are increasingly being abandoned in clinical practice, and that early, permissive weight-bearing in select cases is not associated with a higher degree of complications [\u003cspan citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e, \u003cspan citationid=\"CR50\" class=\"CitationRef\"\u003e50\u003c/span\u003e]. However, a low-powered study directly measuring postoperative joint subsidence through radio stereometrics analysis has shown that higher average knee joint loading during the stance phase of gait is not associated with increased postoperative fracture fragment migration beyond 3 mm [\u003cspan citationid=\"CR50\" class=\"CitationRef\"\u003e50\u003c/span\u003e]. The clinical significance of these increases in step-off formation, particularly in relation to long-term outcomes, remains unclear. The relevance of an individual simulation approach in determining this risk for secondary fracture migration and loss of reduction is evident in the second patient with medial-sided plating. This is the only patient simulated in this analysis with postoperative fracture subsidence and subsequent loosening of a screw in the plate apex, experiencing an outward pushing force running almost parallel to the fracture plane. This patient reported being permissively weight-bearing within the first weeks after the fracture and used no aids for walking, thus exposing her to at least her full body weight. Accordingly, the simulation of the case under full weight-bearing conditions showed the highest amount of fracture area, above safe ranges of interfragmentary motion according to the healing window [\u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e, \u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e, \u003cspan citationid=\"CR48\" class=\"CitationRef\"\u003e48\u003c/span\u003e], confirming the simulation's principal capability to assess situations at risk, already seen in studies [\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e, \u003cspan citationid=\"CR6\" class=\"CitationRef\"\u003e6\u003c/span\u003e]. Interestingly, the fracture in this patient consolidated in this position and has led to a satisfactory result for the patient after screw removal and prescription of partial weight-bearing for 6 weeks.\u003c/p\u003e \u003cp\u003eThe other simulated fracture situations with triple plate osteosynthesis have shown sufficient stability and safe ranges of interfragmentary motion throughout all weight-bearing levels. Accordingly, these fractures exhibited uneventful postoperative treatment courses, with no secondary dislocations or hardware failures. Both patients, however, required more than 8 weeks to gradually wean themselves off their walking aids. This aligns with current clinical studies and review analyses focusing on permissive weight-bearing. While it is safe to allow permissive weight-bearing, patients often require considerable time to regain full weight-bearing [\u003cspan citationid=\"CR34\" class=\"CitationRef\"\u003e34\u003c/span\u003e]. Simulation workflows, such as the one introduced here, can help identify patients who are safe for higher degrees of weight-bearing early during the treatment course and potentially increase their physical therapy training within their simulated safe range, guiding them toward earlier functional recovery [\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e, \u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eThe approach demonstrates the value of a simulation workflow in testing the weight-bearing associated effects on construct stability, joint reaction forces, and fracture healing. Identifying patients at risk for treatment failure early in the fracture course is a potentially significant factor in reducing the patient and socioeconomic burden of disease. On the patient's side, early interventions, ranging from adapting the aftercare regimen to surgical treatment, are possible. Aftercare adaptations can reduce weight-bearing in situations with increased interfragmentary motion or the risk of fixation failure. In contrast, the frequency and intensity of full weight-bearing can be addressed in understimulated situations. Furthermore, individual, simulation-adjusted adaptation of ROM braces could prevent certain critical motions. If the simulation determines that healing cannot be achieved by modulation of the weight-bearing input, the stiffness of the osteosynthetic construct could be adjusted, i.e., through augmentative plating, as well as further biologic measures (autologous bone graft) in mechanically sound situations without clinical healing. By establishing this simulation as a rehabilitation and screening tool, added socioeconomic effects can be expected through better healing rates through adapted therapy and earlier intervention in critical cases. Research on joint reaction forces in arthroplasty has shown that it is not only gait and associated weight-bearing that are putting stress on the proximal tibia, but also different movement situations that can exert high levels of force on a treated joint [\u003cspan citationid=\"CR3\" class=\"CitationRef\"\u003e3\u003c/span\u003e]. The presented workflow and the database of reference movements can be extended to include more scenarios, such as getting out of bed, walking at different speeds, or rising from a chair, to provide a more comprehensive simulation of individual patients\u0026rsquo; movement patterns. Furthermore, this would allow us to test the particular patient in more detail and at a higher level of injury specificity, such as high-degree flexion testing in flexion-type injuries, to adapt postoperative range of motion protocols.\u003c/p\u003e \u003cp\u003eSimulation approaches, such as the one introduced in this article, offer a unique opportunity to enhance our understanding of the effects of postoperative weight-bearing on osteosynthetic construct stability, fracture healing, and, ultimately, patient outcomes. Over the past 30 years, the discussion on potential weight-bearing recommendations following operative fracture treatment of the proximal tibia has remained active and controversial (Segal et al., 1993; Kubiak et al., 2013; Canton et al., 2022). Determining the biomechanical effects of weight-bearing on joint mechanics without computer simulation requires both controlled weight-bearing and precise radiographic measures of joint subsidence and fracture movement early during the fracture course. Limited patient number studies combining both these techniques have been performed showing that increased amounts of weight-bearing after proximal tibia fractures can be allowed without negative radiographic and clinical consequences [\u003cspan citationid=\"CR50\" class=\"CitationRef\"\u003e50\u003c/span\u003e, \u003cspan citationid=\"CR51\" class=\"CitationRef\"\u003e51\u003c/span\u003e], but to get to a comprehensive recommendation on all types of proximal tibia fractures, while considering the many treatment and hardware placement options is not feasible with these highly complex and research-oriented techniques. Clinical studies recommending permissive weight-bearing in these patients have shown that this can be associated with a decreased short-term recovery time, but also with limitations to the amount of weight-bearing, especially at the study endpoint, when the patient converts to a total knee arthroplasty [\u003cspan citationid=\"CR34\" class=\"CitationRef\"\u003e34\u003c/span\u003e]. To safely test these limitations early during the fracture treatment on the individual treatment situation, but safely with simulated, different weight-bearing levels, thus not only offers the opportunity to increase our understanding of safe boundaries during fracture rehabilitation but actually can allow for individualized aftercare concerning weight-bearing with wearable techniques, in situations that would otherwise be hard to assess and control [\u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e, \u003cspan citationid=\"CR41\" class=\"CitationRef\"\u003e41\u003c/span\u003e]. The clinical feasibility of our approach has been demonstrated, and it can now be further refined in larger-scale clinical studies. The model's outcome predictions enable the development of tailored post-operative care plans, ensuring high-risk patients receive the necessary attention to prevent complications. Hospitals can allocate resources more efficiently, reducing healthcare costs by preventing complications and readmissions. Predictive insights enable clinicians to implement early intervention strategies, thereby improving patient outcomes. Additionally, the findings can inform enhanced recovery after surgery protocols, optimizing recovery times and reducing hospital stays.\u003c/p\u003e"},{"header":"5 Limitations","content":"\u003cp\u003eWhile the study provides insightful results, it also offers opportunities for further research and refinement. Including a relatively small number of patients provides a focused initial investigation, paving the way for future studies with larger cohorts to enhance the robustness and applicability of the results. While the simulations do not capture the full biological context of the injury, including concomitant soft tissue damage and the effects of the ligamentous injury on joint stability, they open the door to more comprehensive modeling that incorporates these factors. In addition, the study highlights an important area for further investigation: determining the precise level of mechanical stimuli within the fracture zone that is optimal for healing.\u003c/p\u003e"},{"header":"6 Conclusion","content":"\u003cp\u003eThe introduced model enabled the construction of digital twins for our patients, allowing us to test the effect of different weight-bearing levels on individual construct stiffness, interfragmentary strain, and fracture healing following the clinical course. To safely test different weight-bearing scenarios early in the postoperative course, the model is adaptable to use weight and height-scaled joint reaction force input data from a reference database of healthy participants. Further adaptations of the simulation and validation in large-scale clinical studies are now possible to refine the model\u0026rsquo;s accuracy and predictive capability before its introduction into the clinic.\u003c/p\u003e"},{"header":"Declarations","content":"\u003ch3\u003e1 Conflict of Interest\u003c/h3\u003e\n\u003cp\u003eThe authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.\u003c/p\u003e\n\u003ch3\u003e2 Author Contributions\u003c/h3\u003e\n\u003cp\u003eBB, MR, AA: Conceptualized the study, AA, MR, KW: Performed the simulations and the data analysis, BB, AA, MR: Analysis or interpretation of data and results, BB, TH: Interpretation of the results from a clinical perspective, clinical treatment and decision process, AA: Movement analysis, AA, MR, KW, SD: Interpretation of the results from an engineering perspective, SD, TH: Reviewed the manuscript, SD, BB, MR, TH: Secured funding of the study. All authors contributed to the manuscript and approved the final version.\u003c/p\u003e\n\u003ch3\u003e3 Ethics Statement\u003c/h3\u003e\n\u003cp\u003eThe studies involving humans were approved by the Institutional Ethics Committee of the University of Tuebingen (Project Number 318/2022BO2). All patients who can be identified via images or other information within the manuscript have given their consent. Informed and written consent was obtained from all healthy subjects. The healthy test subjects were also Saarland University members, making them suitable for experiments at the university. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.\u003c/p\u003e\n\u003cp\u003eAll subjects and/or their legal guardian(s) have provided informed consent for the publication of identifying information and/or images in this online open-access publication. This consent was obtained in writing prior to submission and includes approval for the use of any personal or identifiable data presented herein.\u003c/p\u003e\n\u003ch3\u003e4 Data availability\u003c/h3\u003e\n\u003cp\u003eThe original contributions presented in the study are included in the article; further inquiries can be directed to the corresponding author. Researchers who wish to request access to data should send an email indicating the research purpose. Every request must be reviewed by the responsible institutional review boards, considering the risk of patient reidentification and compliance with the applicable data protection rules.\u003c/p\u003e\n\u003ch3\u003e5 Funding\u003c/h3\u003e\n\u003cp\u003eThis study was funded by the German Federal Ministry for Science and Education (BMBF) under the grant \u0026ldquo;VirtuS\u0026rdquo; (FKZ: 13GW0572).\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\u003cli\u003e\u003cspan\u003eArnold, J. B. et al. Characteristics of postoperative weight bearing and management protocols for tibial plateau fractures: Findings from a scoping review. \u003cem\u003eInjury\u003c/em\u003e 48, 12 (2017), 2634\u0026ndash;2642. (2017). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.injury.2017.10.040\u003c/span\u003e\u003cspan address=\"10.1016/j.injury.2017.10.040\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePeter Augat, M. W. et al. Biomechanical models: key considerations in study design. \u003cem\u003eOTA Int.\u003c/em\u003e \u003cb\u003e4\u003c/b\u003e (2021), 2. \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003eE099. https://doi.org/10.1097/OI9.0000000000000099\u003c/span\u003e\u003cspan address=\"E099. 10.1097/OI9.0000000000000099\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBergmann, G. et al. and. Standardized loads acting in knee implants. \u003cem\u003ePLoS One\u003c/em\u003e 9, 1 (2014). (2014). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1371/journal.pone.0086035\u003c/span\u003e\u003cspan address=\"10.1371/journal.pone.0086035\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eIto, K., Bishop, N. E., Tami, I. \u0026amp; Schneider, E. In vivo comparison of early fracture healing under deviatoric and volumetric deformationsitle. \u003cem\u003eActa Bioeng Biomech\u003c/em\u003e 4, (2003), 754\u0026ndash;5. (2003).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBenedikt, J. et al. and Michael Roland. Individualized Determination of the Mechanical Fracture Environment After Tibial Exchange Nailing\u0026mdash;A Simulation-Based Feasibility Study. \u003cem\u003eFront. Surg.\u003c/em\u003e 8, September (2021), 1\u0026ndash;9. (2021). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.3389/fsurg.2021.749209\u003c/span\u003e\u003cspan address=\"10.3389/fsurg.2021.749209\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBenedikt, J. et al. An individualized simulation model based on continuous, independent, ground force measurements after intramedullary stabilization of a tibia fracture. \u003cem\u003eArch. Appl. Mech.\u003c/em\u003e 89, 11 (2019), 2351\u0026ndash;2360. (2019). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1007/s00419-019-01582-5\u003c/span\u003e\u003cspan address=\"10.1007/s00419-019-01582-5\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBenedikt, J. et al. and Tim Pohlemann. Weight-bearing recommendations after operative fracture treatment\u0026mdash;fact or fiction? Gait results with and feasibility of a dynamic, continuous pedobarography insole. \u003cem\u003eInt. Orthop.\u003c/em\u003e 41, 8 (2017), 1507\u0026ndash;1512. (2017). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1007/s00264-017-3481-7\u003c/span\u003e\u003cspan address=\"10.1007/s00264-017-3481-7\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eGeoffrey, T., Burns, J. D., Zendler, Ronald, F. \u0026amp; Zernicke Validation of a wireless shoe insole for ground reaction force measurement. \u003cem\u003eJ. Sports Sci.\u003c/em\u003e 37, 10 (2019), 1129\u0026ndash;1138. (2019). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1080/02640414.2018.1545515\u003c/span\u003e\u003cspan address=\"10.1080/02640414.2018.1545515\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eGianluca Canton, A., Sborgia, M., Dussi, N., Rasio \u0026amp; Murena, L. Early weight bearing in tibial plateau fractures treated with ORIF: a systematic review of literature. \u003cem\u003eJ. Orthop. Surg. Res.\u003c/em\u003e 17, 1 (2022), 1\u0026ndash;8. (2022). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1186/s13018-022-03156-8\u003c/span\u003e\u003cspan address=\"10.1186/s13018-022-03156-8\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eIon Carrera, P. E. et al. An intact fibula may contribute to allow early weight bearing in surgically treated tibial plateau fractures. \u003cem\u003eKnee Surgery, Sport. Traumatol. Arthrosc.\u003c/em\u003e 26, 3 (2018), 756\u0026ndash;761. (2018). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1007/s00167-017-4428-7\u003c/span\u003e\u003cspan address=\"10.1007/s00167-017-4428-7\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eIon Carrera, P. E., Gelber, G., Chary, M. A., Gonz\u0026aacute;lez-Ballester, J. C., Monllau \u0026amp; Jerome Noailly Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration. \u003cem\u003eInt. Orthop.\u003c/em\u003e \u003cb\u003e40\u003c/b\u003e (2016), 2163\u0026ndash;2169. \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1007/s00264-015-3106-y\u003c/span\u003e\u003cspan address=\"10.1007/s00264-015-3106-y\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2016).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCattaneo, P. M., Dalstra, M. \u0026amp; Frich, L. H. A three-dimensional finite element model from computed tomography data: A semi-automated method. \u003cem\u003eProc. Inst. Mech. Eng. Part H J. Eng. Med.\u003c/em\u003e 215, 2 (2001), 203\u0026ndash;213. (2001). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1243/0954411011533760\u003c/span\u003e\u003cspan address=\"10.1243/0954411011533760\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eChristopher, P. et al. Patient compliance with postoperative lower-extremity non-weight-bearing restrictions. \u003cem\u003eJ. Bone Jt. Surg. - Am. Vol\u003c/em\u003e. \u003cb\u003e98\u003c/b\u003e (2016), 1563\u0026ndash;1567. \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.2106/JBJS.15.01054\u003c/span\u003e\u003cspan address=\"10.2106/JBJS.15.01054\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2016).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eClaes, L. E. \u0026amp; Heigele, C. A. Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing. \u003cem\u003eJ. Biomech.\u003c/em\u003e 32, 3 (1999), 255\u0026ndash;266. (1999). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/S0021-9290(98)00153-5\u003c/span\u003e\u003cspan address=\"10.1016/S0021-9290(98)00153-5\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLutz Claes. Improvement of clinical fracture healing \u0026ndash; What can be learned from mechano-biological research? \u003cem\u003eJ. Biomech.\u003c/em\u003e 115, (2021), 110148. (2021). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.jbiomech.2020.110148\u003c/span\u003e\u003cspan address=\"10.1016/j.jbiomech.2020.110148\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLutz, E. C. \u003cem\u003eMechanobiology of Fracture Healing. From Basic Science to Clinical Application\u003c/em\u003e. (2017). Retrieved from \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://link.springer.com/bookseries/10280\u003c/span\u003e\u003cspan address=\"https://link.springer.com/bookseries/10280\" targettype=\"URL\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLutz, E. et al. Effects of mechanical factors on the fracture healing process. \u003cem\u003eClin. Orthop. Relat. Res.\u003c/em\u003e 355, SUPPL. (1998). (1998). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1097/00003086-199810001-00015\u003c/span\u003e\u003cspan address=\"10.1097/00003086-199810001-00015\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCharles, M., Court-Brown \u0026amp; Caesar, B. Epidemiology of adult fractures: A review. \u003cem\u003eInjury\u003c/em\u003e 37, 8 (2006), 691\u0026ndash;697. (2006). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.injury.2006.04.130\u003c/span\u003e\u003cspan address=\"10.1016/j.injury.2006.04.130\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBrian, P. et al. Fracture healing: A review of clinical, imaging and laboratory diagnostic options. \u003cem\u003eInjury\u003c/em\u003e 48, (2017), S69\u0026ndash;S75. (2017). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.injury.2017.04.020\u003c/span\u003e\u003cspan address=\"10.1016/j.injury.2017.04.020\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHannah, L. et al. Virtual Mechanical Testing Based on Low-Dose. \u003cem\u003eJ. Bone Jt. Surg.\u003c/em\u003e 101, 13 (2019), 1193\u0026ndash;1202. (2019). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.2106/JBJS.18.01139\u003c/span\u003e\u003cspan address=\"10.2106/JBJS.18.01139\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eScott, L. et al. OpenSim: Open-source software to create and analyze dynamic simulations of movement. \u003cem\u003eIEEE Trans. Biomed. Eng.\u003c/em\u003e \u003cb\u003e54\u003c/b\u003e (2007), 1940\u0026ndash;1950. \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1109/TBME.2007.901024\u003c/span\u003e\u003cspan address=\"10.1109/TBME.2007.901024\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2007).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDoblar\u0026eacute;, M., Garc\u0026iacute;a, J. M. \u0026amp; G\u0026oacute;mez, M. J. Modelling bone tissue fracture and healing: A review. \u003cem\u003eEng. Fract. Mech.\u003c/em\u003e 71, 13\u0026ndash;14 (2004), 1809\u0026ndash;1840. (2004). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.engfracmech.2003.08.003\u003c/span\u003e\u003cspan address=\"10.1016/j.engfracmech.2003.08.003\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eEdwards, W. B., Schnitzer, T. J. \u0026amp; Troy, K. L. Torsional stiffness and strength of the proximal tibia are better predicted by finite element models than DXA or QCT. \u003cem\u003eJ. Biomech.\u003c/em\u003e 46, 10 (2013), 1655\u0026ndash;1662. (2013). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.jbiomech.2013.04.016\u003c/span\u003e\u003cspan address=\"10.1016/j.jbiomech.2013.04.016\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRichardson, J. B., Garcia, J. M., Kuiper, J. H. \u0026amp; Doblare, M. A numerical model to study the mechanical influences on bone fracture healing. \u003cem\u003eActa Bioeng Biomech\u003c/em\u003e 4, (2003), 394\u0026ndash;5. (2003).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eGaston, P., Will, E. M. \u0026amp; Keating, J. F. Recovery of knee function following fracture of the tibial plateau. \u003cem\u003eJ. Bone Jt. Surg. - Ser. B\u003c/em\u003e 87, 9 (2005), 1233\u0026ndash;1236. (2005). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1302/0301-620X.87B9.16276\u003c/span\u003e\u003cspan address=\"10.1302/0301-620X.87B9.16276\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eGeetha, M., Singh, A. K., Asokamani, R. \u0026amp; Gogia, A. K. Ti based biomaterials, the ultimate choice for orthopaedic implants - A review. \u003cem\u003eProg Mater. Sci.\u003c/em\u003e \u003cb\u003e54\u003c/b\u003e (2009), 397\u0026ndash;425. \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.pmatsci.2008.06.004\u003c/span\u003e\u003cspan address=\"10.1016/j.pmatsci.2008.06.004\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2009).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMohammad, S., Ghiasi, J., Chen, A., Vaziri, E. K. \u0026amp; Rodriguez and Ara Nazarian. Bone fracture healing in mechanobiological modeling: A review of principles and methods. \u003cem\u003eBone Reports\u003c/em\u003e 6, (2017), 87\u0026ndash;100. (2017). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.bonr.2017.03.002\u003c/span\u003e\u003cspan address=\"10.1016/j.bonr.2017.03.002\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBernd Heinlein, I. et al. and Georg Bergmann. ESB clinical biomechanics award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6\u0026ndash;10 months. \u003cem\u003eClin. Biomech.\u003c/em\u003e 24, 4 (2009), 315\u0026ndash;326. (2009). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.clinbiomech.2009.01.011\u003c/span\u003e\u003cspan address=\"10.1016/j.clinbiomech.2009.01.011\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBenedikt Helgason, E., Perilli, E., Schileo, F., Taddei, S. \u0026amp; Brynj\u0026oacute;lfsson and Marco Viceconti. Mathematical relationships between bone density and mechanical properties: A literature review. \u003cem\u003eClin. Biomech.\u003c/em\u003e 23, 2 (2008), 135\u0026ndash;146. (2008). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.clinbiomech.2007.08.024\u003c/span\u003e\u003cspan address=\"10.1016/j.clinbiomech.2007.08.024\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eIvan Hvid, S. M., Bentzen, F., Linde, L., Mosekilde \u0026amp; Pongsoipetch, B. X-ray quantitative computed tomography: The relations to physical properties of proximal tibial trabecular bone specimens. \u003cem\u003eJ. Biomech.\u003c/em\u003e 22, 8\u0026ndash;9 (1989), 837\u0026ndash;844. (1989). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/0021-9290(89)90067-5\u003c/span\u003e\u003cspan address=\"10.1016/0021-9290(89)90067-5\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eNurul, I. I., Ahmad, M. S. \u0026amp; Zulfarina, M. S. Sharifah Nurul Aqilah Sayed Mohd Zaris, Zainal Abidin Nor Azlin, Isa Naina Mohamed, Norazlina Mohamed, Sabarul Afian Mokhtar, and Ahmad Nazrun Shuid. 2019. Physical function assessment of older adults with lower body fractures at 3 months post-discharge from hospital. \u003cem\u003eTher. Clin. Risk Manag\u003c/em\u003e. \u003cb\u003e15\u003c/b\u003e, 201\u0026ndash;210. \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.2147/TCRM.S189748\u003c/span\u003e\u003cspan address=\"10.2147/TCRM.S189748\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2019).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eEfthymios Iliopoulos and Nikiforos Galanis. Physiotherapy after tibial plateau fracture fixation: A systematic review of the literature. \u003cem\u003eSAGE Open Med.\u003c/em\u003e 8, (2020). (2020). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1177/2050312120965316\u003c/span\u003e\u003cspan address=\"10.1177/2050312120965316\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eImam, A. C. M.A., Fraker. Titanium Alloys as Implant Materials. \u003cem\u003eMater. Sci.\u003c/em\u003e (1996), 3\u0026ndash;16. (1996).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKalmet, P. H. S. et al. and Martijn Poeze. Patient-reported quality of life and pain after permissive weight bearing in surgically treated trauma patients with tibial plateau fractures: a retrospective cohort study. \u003cem\u003eArch. Orthop. Trauma Surg.\u003c/em\u003e 139, 4 (2019), 483\u0026ndash;488. (2019). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1007/s00402-018-3088-5\u003c/span\u003e\u003cspan address=\"10.1007/s00402-018-3088-5\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKammerlander, C. et al. Inability of older adult patients with hip fracture to maintain postoperative weight-bearing restrictions. \u003cem\u003eJ. Bone Jt. Surg. - Am. Vol.\u003c/em\u003e 100, 11 (2018), 936\u0026ndash;941. (2018). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.2106/JBJS.17.01222\u003c/span\u003e\u003cspan address=\"10.2106/JBJS.17.01222\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eNikolas, K., Knowles, J. M., Reeves \u0026amp; Ferreira, L. M. Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature. \u003cem\u003eJ. Exp. Orthop.\u003c/em\u003e 3, 1 (2016). (2016). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1186/s40634-016-0072-2\u003c/span\u003e\u003cspan address=\"10.1186/s40634-016-0072-2\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMorten, T., Kristensen, N. B. \u0026amp; Foss and Henrik Kehlet. Timed Up \u0026amp; Go Test as a Predictor of Falls Within 6 Months After Hip Fracture Surgery. 87, 1 (2007). (2007).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eErik, N. et al. Early weight bearing after lower extremity fractures in adults. \u003cem\u003eJ. Am. Acad. Orthop. Surg.\u003c/em\u003e 21, 12 (2013), 727\u0026ndash;738. (2013). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.5435/JAAOS-21-12-727\u003c/span\u003e\u003cspan address=\"10.5435/JAAOS-21-12-727\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eAndersen, M. S., Damsgaard, M. \u0026amp; Rasmussen, J. Kinematic analysis of over-determinate biomechanical systems. \u003cem\u003eComput. Methods Biomech. Biomed. Engin.\u003c/em\u003e 12, 4 (2009), 371\u0026ndash;384. (2009).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMeir, T., Marmor, H., Dailey, R., Marcucio \u0026amp; Hunt, A. C. Biomedical research models in the science of fracture healing - Pitfalls \u0026amp; promises. \u003cem\u003eInjury\u003c/em\u003e 51, 10 (2020), 2118\u0026ndash;2128. (2020). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.injury.2020.06.025\u003c/span\u003e\u003cspan address=\"10.1016/j.injury.2020.06.025\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMeir, T. et al. Use of Wearable Technology to Measure Activity in Orthopaedic Trauma Patients: A Systematic Review. \u003cem\u003eIndian J. Orthop.\u003c/em\u003e 56, 7 (2022), 1112\u0026ndash;1122. (2022). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1007/s43465-022-00629-0\u003c/span\u003e\u003cspan address=\"10.1007/s43465-022-00629-0\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eIain, R. et al. Surgical fixation methods for tibial plateau fractures. \u003cem\u003eCochrane Database Syst. Rev.\u003c/em\u003e 2015, 9 (2015). (2015). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1002/14651858.CD009679.pub2\u003c/span\u003e\u003cspan address=\"10.1002/14651858.CD009679.pub2\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eAlvaro Muro-de-la-Herran. Bego\u0026ntilde;a Garc\u0026iacute;a-Zapirain, and Amaia M\u0026eacute;ndez-Zorrilla. 2014. Gait analysis methods: An overview of wearable and non-wearable systems, highlighting clinical applications. \u003cem\u003eSens. (Switzerland)\u003c/em\u003e. \u003cb\u003e14\u003c/b\u003e (2), 3362\u0026ndash;3394. \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.3390/s140203362\u003c/span\u003e\u003cspan address=\"10.3390/s140203362\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2014).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePodsiadlo, S. \u0026amp; Richardson, D. The Timed Up and Go: A Test of Basic Functional Mobility for Frail Elderly Persons. \u003cem\u003eJ. Am. Geriatr. Soc.\u003c/em\u003e 39, 2 (1991), 142\u0026ndash;148. (1991).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRho, J. Y., Hobatho, M. C. \u0026amp; Ashman, R. B. Relations of mechanical properties to density and CT numbers in human bone. \u003cem\u003eMed. Eng. Phys.\u003c/em\u003e \u003cb\u003e17\u003c/b\u003e (1995), 347\u0026ndash;355. \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/1350-4533(95)97314-F\u003c/span\u003e\u003cspan address=\"10.1016/1350-4533(95)97314-F\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (1995).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePeter Schwarzenberg, K., Klein, S. J., Ferguson \u0026amp; Dailey, H. L. Brigitte von Rechenberg, Salim Darwiche, and Virtual mechanical tests out-perform morphometric measures for assessment of mechanical stability of fracture healing in vivo. \u003cem\u003eJ. Orthop. Res.\u003c/em\u003e 39, 4 (2021), 727\u0026ndash;738. (2021). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1002/jor.24866\u003c/span\u003e\u003cspan address=\"10.1002/jor.24866\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWhitelaw, G. P., Segal, D., Mallik, A. R., Wetzler, M. J. \u0026amp; Franchi, A. V. Early weight bearing of lateral tibial plateau fractures. \u003cem\u003eClin. Orthop. Relat. Res.\u003c/em\u003e (1993), Sep 1;294:232-7. (1993).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSandra, J., Shefelbine, P., Augat, L., Claes \u0026amp; Simon, U. Trabecular bone fracture healing simulation with finite element analysis and fuzzy logic. \u003cem\u003eJ. Biomech.\u003c/em\u003e 38, 12 (2005), 2440\u0026ndash;2450. (2005). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.jbiomech.2004.10.019\u003c/span\u003e\u003cspan address=\"10.1016/j.jbiomech.2004.10.019\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSingleton, N., Sahakian, V. \u0026amp; Muir, D. Outcome after Tibial Plateau Fracture: How Important Is Restoration of Articular Congruity? \u003cem\u003eJ. Orthop. Trauma\u003c/em\u003e 31, 3 (2017), 158\u0026ndash;163. (2017). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1097/BOT.0000000000000762\u003c/span\u003e\u003cspan address=\"10.1097/BOT.0000000000000762\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDominic Thewlis, S. A., Callary, F., Fraysse \u0026amp; Solomon, L. B. Peak loading during walking is not associated with fracture migration following tibial plateau fracture: A preliminary case series. \u003cem\u003eJ. Orthop. Res.\u003c/em\u003e \u003cb\u003e33\u003c/b\u003e (2015), 1398\u0026ndash;1406. \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1002/jor.22905\u003c/span\u003e\u003cspan address=\"10.1002/jor.22905\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2015).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDominic Thewlis, F. et al. Postoperative weight bearing and patient reported outcomes at one year following tibial plateau fractures. \u003cem\u003eInjury\u003c/em\u003e 48, 7 (2017), 1650\u0026ndash;1656. (2017). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.injury.2017.05.024\u003c/span\u003e\u003cspan address=\"10.1016/j.injury.2017.05.024\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eNir Trabelsi, Z., Yosibash \u0026amp; Milgrom, C. Validation of subject-specific automated p-FE analysis of the proximal femur. \u003cem\u003eJ. Biomech.\u003c/em\u003e 42, 3 (2009), 234\u0026ndash;241. (2009). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.jbiomech.2008.10.039\u003c/span\u003e\u003cspan address=\"10.1016/j.jbiomech.2008.10.039\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003evan der Vusse, M. et al. Is the AO guideline for postoperative treatment of tibial plateau fractures still decisive? A survey among orthopaedic surgeons and trauma surgeons in the Netherlands. \u003cem\u003eArch. Orthop. Trauma Surg.\u003c/em\u003e 137, 8 (2017), 1071\u0026ndash;1075. (2017). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1007/s00402-017-2718-7\u003c/span\u003e\u003cspan address=\"10.1007/s00402-017-2718-7\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKerstin Wickert, M. et al. and. Experimental and virtual testing of bone-implant systems equipped with the AO Fracture Monitor with regard to interfragmentary movement. \u003cem\u003eFront. Bioeng. Biotechnol.\u003c/em\u003e 12, March (2024), 1\u0026ndash;20. (2024). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.3389/fbioe.2024.1370837\u003c/span\u003e\u003cspan address=\"10.3389/fbioe.2024.1370837\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWilliamson, M., Iliopoulos, E., Jain, A., Ebied, W. \u0026amp; Trompeter, A. Immediate weight bearing after plate fixation of fractures of the tibial plateau. \u003cem\u003eInjury\u003c/em\u003e 49, 10 (2018), 1886\u0026ndash;1890. (2018). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.injury.2018.06.039\u003c/span\u003e\u003cspan address=\"10.1016/j.injury.2018.06.039\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZohar Yosibash, R., Padan, L. \u0026amp; Joskowicz and Charles Milgrom. A CT-based high-order finite element analysis of the human proximal femur compared to in-vitro experiments. \u003cem\u003eJ. Biomech. Eng.\u003c/em\u003e 129, 3 (2007), 297\u0026ndash;309. (2007). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1115/1.2720906\u003c/span\u003e\u003cspan address=\"10.1115/1.2720906\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCinzia Zannoni, R., Mantovani \u0026amp; Viceconti, M. Material properties assignment to finite element models of bone structures: A new method. \u003cem\u003eMed. Eng. Phys.\u003c/em\u003e 20, 10 (1999), 735\u0026ndash;740. (1999). \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/S1350-4533(98)00081-2\u003c/span\u003e\u003cspan address=\"10.1016/S1350-4533(98)00081-2\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e\u003c/ol\u003e"}],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":true,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":true,"highlight":"","institution":"","isAcceptedByJournal":false,"isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"
[email protected]","identity":"researchsquare","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":true,"externalIdentity":"","sideBox":"","snPcode":"","submissionUrl":"/submission","title":"Research Square","twitterHandle":"researchsquare","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"","reportingPortfolio":"","inReviewEnabled":false,"inReviewRevisionsEnabled":true},"keywords":"","lastPublishedDoi":"10.21203/rs.3.rs-6546928/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-6546928/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003cp\u003e\u003cem\u003ePurpose\u003c/em\u003e\u003c/p\u003e\n\u003cp\u003eThe prescribed amount of weight-bearing after tibial plateau fractures is controversial because it affects osteosynthetic construct stability and fracture healing. We aim to introduce a simulation model that adequately predicts the effects of different weight-bearing amounts on stability and healing, based on the patient’s individual fracture pattern and treatment construct.\u003c/p\u003e\n\u003cp\u003e\u003cem\u003eMethods\u003c/em\u003e\u003c/p\u003e\n\u003cp\u003eTo safely test different amounts of weight-bearing limits, we first extracted knee joint forces for different weight-bearing limits from musculoskeletal simulation based on monitoring data of 22 uninjured participants. Correct loading was ensured with a force-measuring insole. We then tested three patients after tibial plateau fracture with their current weight-bearing level and constructed a simulation model determining implant stress, knee joint force, and fracture gap interfragmentary strain. The patient-specific weight-bearing level was then substituted for weight-normalized uninjured participant data to test different weight-bearing levels in the simulation model.\u003c/p\u003e\n\u003cp\u003e\u003cem\u003eResults\u003c/em\u003e\u003c/p\u003e\n\u003cp\u003eThe simulation model calculated individual construct stiffness and interfragmentary strain at different weight-bearing levels following the clinical course. When comparing the patient's individual weight-bearing input with the weight-normalized input of the uninjured participants at the same level, comparable knee joint forces were extracted, showing the feasibility of this approach.\u003c/p\u003e\n\u003cp\u003e\u003cem\u003eConclusion\u003c/em\u003e\u003c/p\u003e\n\u003cp\u003eUsing an adapted reference movement database, the model allows the determination of safe weight-bearing ranges concerning construct stability and fracture healing based on individual fracture morphology and treatment without exposing patients to excessive weight-bearing. Future studies can test this approach in more extensive patient-number studies and different treatment situations.\u003c/p\u003e","manuscriptTitle":"Predicting the Effect of Individual Weight-Bearing on Tibial Load and Fracture Healing after Tibial Plateau Fractures – Introduction of a Biomechanical Simulation Model","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2025-05-22 10:05:40","doi":"10.21203/rs.3.rs-6546928/v1","editorialEvents":[{"type":"communityComments","content":0}],"status":"published","journal":{"display":true,"email":"
[email protected]","identity":"researchsquare","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":true,"externalIdentity":"","sideBox":"","snPcode":"","submissionUrl":"/submission","title":"Research Square","twitterHandle":"researchsquare","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"","reportingPortfolio":"","inReviewEnabled":false,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"65b62efb-6d23-44c3-92a0-1b19f107ef15","owner":[],"postedDate":"May 22nd, 2025","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"posted","subjectAreas":[{"id":48795861,"name":"Biological sciences/Computational biology and bioinformatics/Computational models"},{"id":48795862,"name":"Health sciences/Health care/Fracture repair"}],"tags":[],"updatedAt":"2025-06-17T07:24:38+00:00","versionOfRecord":[],"versionCreatedAt":"2025-05-22 10:05:40","video":"","vorDoi":"","vorDoiUrl":"","workflowStages":[]},"version":"v1","identity":"rs-6546928","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-6546928","identity":"rs-6546928","version":["v1"]},"buildId":"8U1c8b4HqxoKbykW_rLl7","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.