Sub-second Extracellular Impedance Measurement of Epithelial Cell Monolayers using Step Excitations and Time-domain Analysis

preprint OA: closed

Abstract

Extracellular electrochemical impedance spectroscopy (EIS) is emerging as a powerful technique in in vitro epithelial research, offering quantitative insights into barrier integrity, morphology, and apical-basolateral polarity noninvasively through metrics such as transepithelial electrical resistance (TER/TEER), transepithelial capacitance (TEC), and membrane ratio ( α ), respectively. However, due to the broad range of frequencies probed, EIS typically requires tens of seconds per measurement, limiting its ability to capture more rapid biological phenomena. We present Time-domain Epithelial Impedance Measurement (TEIM), a method for sub-second extracellular impedance measurements of epithelial cell monolayers based on step (Heaviside function) current excitation and time-domain analysis of the voltage transients, without the need for Fourier transforms. We experimentally demonstrate TEIM measuring TER, TEC, α , and model-derived impedance spectrum at ∼0.3 s sampling rate, which represents a 100- fold improvement in time resolution compared with traditional EIS. The accuracy and precision of TEIM were benchmarked against EIS on both electrical circuits and epithelial cell monolayers of immortalized Human Bronchial Epithelial (16HBE) and Human Colorectal Adenocarcinoma (Caco-2) (n = 3 for each), and average percent errors for TER, TEC, and α ranged from 0.17-3.55%, 1.13-8.96%, and 0.59-26.35%, respectively. Application of TEIM to monitor Caco-2 responses to saponin, a quick-acting pore-forming detergent, revealed smoothly gated double-exponential transient TER and TEC dynamics that were too rapid to be adequately captured previously using EIS. Overall, TEIM enables electrophysiology studies of rapid changes in epithelial cell culture models and possibly more complex in vitro models, holding promise for future applications in areas such as disease modeling, therapeutic development, and beyond.
Full text 2,112 characters · extracted from oa-html · click to expand
Abstract Extracellular electrochemical impedance spectroscopy (EIS) is emerging as a powerful technique in in vitro epithelial research, offering quantitative insights into barrier integrity, morphology, and apical-basolateral polarity noninvasively through metrics such as transepithelial electrical resistance (TER/TEER), transepithelial capacitance (TEC), and membrane ratio ( α ), respectively. However, due to the broad range of frequencies probed, EIS typically requires tens of seconds per measurement, limiting its ability to capture more rapid biological phenomena. We present Time-domain Epithelial Impedance Measurement (TEIM), a method for sub-second extracellular impedance measurements of epithelial cell monolayers based on step (Heaviside function) current excitation and time-domain analysis of the voltage transients, without the need for Fourier transforms. We experimentally demonstrate TEIM measuring TER, TEC, α , and model-derived impedance spectrum at ∼0.3 s sampling rate, which represents a 100- fold improvement in time resolution compared with traditional EIS. The accuracy and precision of TEIM were benchmarked against EIS on both electrical circuits and epithelial cell monolayers of immortalized Human Bronchial Epithelial (16HBE) and Human Colorectal Adenocarcinoma (Caco-2) (n = 3 for each), and average percent errors for TER, TEC, and α ranged from 0.17-3.55%, 1.13-8.96%, and 0.59-26.35%, respectively. Application of TEIM to monitor Caco-2 responses to saponin, a quick-acting pore-forming detergent, revealed smoothly gated double-exponential transient TER and TEC dynamics that were too rapid to be adequately captured previously using EIS. Overall, TEIM enables electrophysiology studies of rapid changes in epithelial cell culture models and possibly more complex in vitro models, holding promise for future applications in areas such as disease modeling, therapeutic development, and beyond. Full Text Availability The license terms selected by the author(s) for this preprint version do not permit archiving in PMC. The full text is available from the preprint server.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-07-26T06:48:27.953686+00:00