Sensitivity, Specificity and Predictive Values of the Rapid Antigen Diagnosis Test of SARS-CoV-2 Virus Panbio COVID-19 at the Patient Screening Point of Hospital Geral De Luanda, Angola

preprint OA: gold CC-BY-4.0
📄 Open PDF View at publisher

Abstract

Abstract Introduction: Alternative forms of diagnosis that are simpler than NAAT and with faster results (15–30 min) were developed based on the direct detection of SARS-CoV-2 viral proteins in nasal swabs and other respiratory tract secretions using a lateral flow immunoassay also called a rapid diagnostic test of antigen detection. The WHO recommends that these tests have at least a sensitivity of 80% and a specificity of 97% when compared to the reference test, the RT-PCR. We evaluated the performance of the rapid antigen detection test Panbio COVID-19 at a patient triage point at the Luanda General Hospital. Methods: A cross-sectional study of a prospective nature was carried out with the inclusion of 37 suspected symptomatic cases without a previous diagnosis of COVID-19. The database was created and processed in MedCal version 19.6. Sensitivity, specificity, positive and negative predictive value and accuracy are expressed in percentages with the respective 95% confidence intervals determined using a 2x2 table. Qualitative variables were presented in absolute and relative frequency. The McNemar's test was used to calculate the proportion of RAD test results Panbio COVID-19 in relation to the RT –PCR and a bilateral P value < 0.05 calculated based on the cumulative binomial distribution was considered significant. Results: In our study, 26 (70.3%) of the cases were male, and the mean age was 18 years, with a standard deviation of 14.8, with 14 (37.8%) residing in the municipality of Talatona. Regarding the days of evolution of symptoms, 34 (91.9%) had symptoms with one week of evolution. The RAD test Panbio COVID-19 had a sensitivity of 54.5% (CI 95% 23.3 – 83.2) and specificity of 96.1% (CI 95% 80.3 – 99.9). The positive and negative predictive value was 85.7% (95% CI 44.9 – 97.7) and 83.3% (95% CI 72.2– 90.5) respectively. The accuracy of the test was 83.7% (95% CI 67.9 – 93.8). The difference between the prevalence in the test Panbio COVID-19 and in RT-PCR it was 10.8% (95% CI -1.6 – 23.3), not being statistically significant (P=0.22). As for the cycle threshold, 71.4% of the samples that were positive for RAD test Panbio COVID-19 had a cycle threshold ≤ 25. Conclusion: The RAD test Panbio COVID-19 did not meet the minimum accuracy requirements recommended by the WHO. However, the predictive values were considerably high in symptomatic subjects.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-21T02:00:01.467718+00:00
License: CC-BY-4.0