Monitoring Military Pilots with Textile Sensors: Physiological Responses and Signal Quality Under Extreme Conditions

preprint OA: closed CC-BY-NC-ND-4.0
📄 Open PDF Full text JSON View at publisher

Abstract

Military pilots are exposed to severe physiological challenges during their missions that may affect cognitive and physical performance. Therefore, continuous monitoring potentially provides critical insights about the impact of extreme condition exposure on the fitness for duty of military pilots. We applied a textile-based monitoring system during training sessions with pilot aspirants to investigate the impact of hypobaric hypoxia and high G-force exposures on the signal quality obtained for a 1-lead electrocardiogram (ECG) and chest excursions. The physiological variables considered were heart rate, heart rate variability, as well as respiratory frequency and respiratory amplitude. In general, 92% and 82% of the recorded ECG time segments during hypoxia and G-force exposure, respectively, were classified as plausible for further analysis. For respiratory data, 72% and 76% were classified as accurate for further data analysis and interpretation. Detailed information about signal quality was found to be critical for the assessment of physiological variables recorded in extreme conditions. Furthermore, the combination of various physiological signals allows for a more holistic interpretation of body responses, for the assessment of body tolerances and an early detection of possible physical and cognitive impairments.
Full text 48,401 characters · extracted from preprint-html · click to expand
Monitoring Military Pilots with Textile Sensors: Physiological Responses and Signal Quality Under Extreme Conditions | medRxiv /* */ /* */ <!-- <!-- /*! * yepnope1.5.4 * (c) WTFPL, GPLv2 */ (function(a,b,c){function d(a){return"[object Function]"==o.call(a)}function e(a){return"string"==typeof a}function f(){}function g(a){return!a||"loaded"==a||"complete"==a||"uninitialized"==a}function h(){var a=p.shift();q=1,a?a.t?m(function(){("c"==a.t?B.injectCss:B.injectJs)(a.s,0,a.a,a.x,a.e,1)},0):(a(),h()):q=0}function i(a,c,d,e,f,i,j){function k(b){if(!o&&g(l.readyState)&&(u.r=o=1,!q&&h(),l.onload=l.onreadystatechange=null,b)){"img"!=a&&m(function(){t.removeChild(l)},50);for(var d in y[c])y[c].hasOwnProperty(d)&&y[c][d].onload()}}var j=j||B.errorTimeout,l=b.createElement(a),o=0,r=0,u={t:d,s:c,e:f,a:i,x:j};1===y[c]&&(r=1,y[c]=[]),"object"==a?l.data=c:(l.src=c,l.type=a),l.width=l.height="0",l.onerror=l.onload=l.onreadystatechange=function(){k.call(this,r)},p.splice(e,0,u),"img"!=a&&(r||2===y[c]?(t.insertBefore(l,s?null:n),m(k,j)):y[c].push(l))}function j(a,b,c,d,f){return q=0,b=b||"j",e(a)?i("c"==b?v:u,a,b,this.i++,c,d,f):(p.splice(this.i++,0,a),1==p.length&&h()),this}function k(){var a=B;return a.loader={load:j,i:0},a}var l=b.documentElement,m=a.setTimeout,n=b.getElementsByTagName("script")[0],o={}.toString,p=[],q=0,r="MozAppearance"in l.style,s=r&&!!b.createRange().compareNode,t=s?l:n.parentNode,l=a.opera&&"[object Opera]"==o.call(a.opera),l=!!b.attachEvent&&!l,u=r?"object":l?"script":"img",v=l?"script":u,w=Array.isArray||function(a){return"[object Array]"==o.call(a)},x=[],y={},z={timeout:function(a,b){return b.length&&(a.timeout=b[0]),a}},A,B;B=function(a){function b(a){var a=a.split("!"),b=x.length,c=a.pop(),d=a.length,c={url:c,origUrl:c,prefixes:a},e,f,g;for(f=0;f<d;f++)g=a[f].split("="),(e=z[g.shift()])&&(c=e(c,g));for(f=0;f<b;f++)c=x[f](c);return c}function g(a,e,f,g,h){var i=b(a),j=i.autoCallback;i.url.split(".").pop().split("?").shift(),i.bypass||(e&&(e=d(e)?e:e[a]||e[g]||e[a.split("/").pop().split("?")[0]]),i.instead?i.instead(a,e,f,g,h):(y[i.url]?i.noexec=!0:y[i.url]=1,f.load(i.url,i.forceCSS||!i.forceJS&&"css"==i.url.split(".").pop().split("?").shift()?"c":c,i.noexec,i.attrs,i.timeout),(d(e)||d(j))&&f.load(function(){k(),e&&e(i.origUrl,h,g),j&&j(i.origUrl,h,g),y[i.url]=2})))}function h(a,b){function c(a,c){if(a){if(e(a))c||(j=function(){var a=[].slice.call(arguments);k.apply(this,a),l()}),g(a,j,b,0,h);else if(Object(a)===a)for(n in m=function(){var b=0,c;for(c in a)a.hasOwnProperty(c)&&b++;return b}(),a)a.hasOwnProperty(n)&&(!c&&!--m&&(d(j)?j=function(){var a=[].slice.call(arguments);k.apply(this,a),l()}:j[n]=function(a){return function(){var b=[].slice.call(arguments);a&&a.apply(this,b),l()}}(k[n])),g(a[n],j,b,n,h))}else!c&&l()}var h=!!a.test,i=a.load||a.both,j=a.callback||f,k=j,l=a.complete||f,m,n;c(h?a.yep:a.nope,!!i),i&&c(i)}var i,j,l=this.yepnope.loader;if(e(a))g(a,0,l,0);else if(w(a))for(i=0;i (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0];var j=d.createElement(s);var dl=l!='dataLayer'?'&l='+l:'';j.src='//www.googletagmanager.com/gtm.js?id='+i+dl;j.type='text/javascript';j.async=true;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-P4HH5NV'); Skip to main content Home About Submit ALERTS / RSS Search for this keyword Advanced Search Monitoring Military Pilots with Textile Sensors: Physiological Responses and Signal Quality Under Extreme Conditions View ORCID Profile René M. Rossi , Frederik Bauer , Andreas Stier , Dennis Bron , View ORCID Profile Simon Annaheim doi: https://doi.org/10.1101/2025.09.03.25332904 René M. Rossi 1 Empa, Swiss Laboratories for Materials Science and Technology, Laboratory for Biomimetic membranes and textiles , St. Gallen, Switzerland 2 ETH, Department of Health Sciences and Technology , Zurich, Switherland Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for René M. Rossi Frederik Bauer 1 Empa, Swiss Laboratories for Materials Science and Technology, Laboratory for Biomimetic membranes and textiles , St. Gallen, Switzerland Find this author on Google Scholar Find this author on PubMed Search for this author on this site Andreas Stier 3 Armasuisse , Bern, Switzerland Find this author on Google Scholar Find this author on PubMed Search for this author on this site Dennis Bron 4 Swiss Air Force, Aeromedical Center , Dubendorf, Switzerland Find this author on Google Scholar Find this author on PubMed Search for this author on this site Simon Annaheim 1 Empa, Swiss Laboratories for Materials Science and Technology, Laboratory for Biomimetic membranes and textiles , St. Gallen, Switzerland Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Simon Annaheim For correspondence: simon.annaheim{at}empa.ch Abstract Full Text Info/History Metrics Data/Code Preview PDF Abstract Military pilots are exposed to severe physiological challenges during their missions that may affect cognitive and physical performance. Therefore, continuous monitoring potentially provides critical insights about the impact of extreme condition exposure on the fitness for duty of military pilots. We applied a textile-based monitoring system during training sessions with pilot aspirants to investigate the impact of hypobaric hypoxia and high G-force exposures on the signal quality obtained for a 1-lead electrocardiogram (ECG) and chest excursions. The physiological variables considered were heart rate, heart rate variability, as well as respiratory frequency and respiratory amplitude. In general, 92% and 82% of the recorded ECG time segments during hypoxia and G-force exposure, respectively, were classified as plausible for further analysis. For respiratory data, 72% and 76% were classified as accurate for further data analysis and interpretation. Detailed information about signal quality was found to be critical for the assessment of physiological variables recorded in extreme conditions. Furthermore, the combination of various physiological signals allows for a more holistic interpretation of body responses, for the assessment of body tolerances and an early detection of possible physical and cognitive impairments. 1. Introduction Military pilots are exposed to severe physiological challenges that may infringe on their physical and cognitive performance ( 1 ). Exposures such as high multiaxial g-forces and rotation, hypoxic conditions, radiation sources and high temperatures, or vibration and noise can lead to a reduction in their physical and mental performance, as demonstrated for severe hypoxic exposures ( 2 ). This extraordinary physical strain requires increased physical and mental activities of the pilot to cope with stressors and to perform the flight tasks at a high level of accuracy. A higher activation level of pilots results in increased respiratory activity and an increase in heart rate ( 3 ), and a decrease in heart rate variability (HRV) ( 4 ). Furthermore, blood lactate concentration during hyperpnoea was found to be higher in hypoxia ( 5 ). Bustamante-Sánchez et al. ( 6 ) analyzed the psychophysiological responses of the participants in incremental hypoxia training (3 minutes at sea level, 8 minutes at 5,000 meters, and a maximum of 10 minutes at 7500 meters above sea level. They reported statistically significant decreases in blood oxygen saturation and increases in heart rate mean values during hypoxia. Also, a significant increase in the rating of perceived exertion was reported during hypoxia. Impairments of cognitive performance have also frequently been reported under high-altitude exposures ( 7 ). Gravity-induced loss of consciousness (G-LOC) is caused by G acceleration stress and is one of the most life- threatening problems for pilots ( 8 ). A study from the UK Royal Air Force in 2017 revealed that 120 (14.8%) aircrew reported at least one episode of G-LOC, and in 260 cases (32.2%), at least one episode of almost loss of consciousness (A-LOC) occurred ( 9 ). The authors showed that the prevalence of reported G-LOC had decreased compared to an earlier survey in 2005 and concluded that this result might be due to the introduction of centrifuge training. The tolerance of the human body to acceleration forces depends on their magnitude, direction and duration, as well as individual factors like age or body weight ( 1 ). To prevent such losses of consciousness, early warning algorithms based on electromyogram (EMG) measurements have been proposed ( 10 ). However, analyses using EMG sensors were restricted to training situations only. Other warning signs proposed are, for example, non-contact measurement systems detecting changes in eye blink rate and head position ( 11 ). A study employing multi-sensory data collection during flight simulations has established a more nuanced understanding of how pilots respond to sudden, critical exposures. The study analyzed subjective feedback from pilots and objective physiological data, creating a reliable index for distress levels and performance capabilities during critical flight phases ( 12 , 13 ). This method substantiates the need for a multidisciplinary approach to pilot evaluation, blending human factors with technology to enhance flight safety. However, the integration of well-validated bio-monitoring systems capable of recording changes in vital signs like heart rate, body temperature, respiration and body motion has not been considered so far ( 14 ). The measurement of physiological parameters, e.g. for the assessment of cognitive task load, has been proposed in several studies since the 1960’s, but the identification of reliable predictors for a reduction in mental or physical performance has been limited by the use of conventional physiological monitoring technologies ( 15 ). Recent studies investigated the possibility of using wearable sensors to assess vital signs like heart rate, respiratory rate or oxygen saturation ( 16 ). Such devices have been commonly used for several years in sports, but not for medical diagnostics due to higher demands on the accuracy and reliability of the systems. The use of multimodal data to predict soldiers’ health and readiness was repeatedly proposed by ( 17 ) while highlighting the need for an accurate assessment based on high-quality data. Challenges of using wearable sensors to assess vital signs in aviation include the accuracy of the sensors used, their robustness to reliably record the vital signs in extreme conditions, as well as the integration in pilot suits and the interference with the pilot’s equipment (Shaw and Harrell 2023). Therefore, a continuous evaluation of the signal quality obtained from sensor recordings is crucial for the interpretation and assessment of the pilot’s readiness. Unfortunately, signal quality assessments are not adequately considered in recent literature (or at least not reported) ( 18 , 19 ). Data is missing about the impact of (severe) environmental working conditions and how this affects the data output of the systems and the accuracy of the further assessment. For field applications, the reliability and robustness of the system are critical aspects for the acceptance of new wearable technologies ( 17 ), as their ease of use and predicted usefulness ( 20 ). The relevance of the monitoring of vital signs and the validity of the predictive models used as early warning parameters has yet to be shown. Among the different types of wearable health monitoring systems, textile-based sensors have emerged as an interesting technology due to their flexibility, softness, breathability, compatibility with pilot clothing, and conformation to each body location, which increases users’ comfort and acceptance, allowing continuous monitoring for extended durations. ( 21 ). However, as these systems are usually not directly attached to the skin, their reliability may suffer from motion artefacts ( 22 ). Consequently, validation is required for each foreseen use case. Our group has very recently validated a textile-based electrocardiogram (ECG) and respiratory monitoring system for sleep apnea monitoring ( 23 ). The goal of the present study was to assess the reliability and accuracy of a very similar monitoring system for potential integration into a medical early warning system designed to monitor pilots and soldiers. This system was worn by the pilots during low-pressure and high-G exposure training. 2. Materials and Methods In the current study, the accuracy and relevance of employing a textile-based monitoring system for monitoring pilots under extreme conditions were evaluated. The monitoring activities were executed during a low-pressure exposure within a chamber and high-G exposures in a high-performance three-axis centrifuge. For the study, a total of 10 healthy pilot aspirants with an average age of 22.6 years (standard deviation [SD]: 2.2y) volunteered to wear the monitoring system during their regular training and qualification blocks, which were conducted according to standard protocols of the Aeromedical Center. The monitoring of the pilots’ vital parameters (ECG, respiration) were conducted in accordance with the Declaration of Helsinki ( 24 ). The Institutional Review Board of the Swiss Aeromedical Center approved the conduct of routine training and qualification modules that are part of pilot education, including the concomitant monitoring of vital signs, and the participants provided written informed consent. 2.1. Textile Monitoring System Throughout the experimental exposures, participants were equipped with a textile monitoring system comprising three distinct sensor types integrated into a belt worn around the chest. The system included two knitted ECG electrodes integrated into the textile assembly for 1-lead ECG recording (along lead I) for the calculation of heart rate (HR) and heart rate variability (HRV) as the SD of RR-intervals (SDNN). A conductive stretch-sensitive textile sensor was applied to measure changes in chest excursion ( Figure 1 ). Based on these measurements, respiratory frequency (fresp) and the respiratory depth (referred to as respiratory sensor elongation amplitude [ampresp]). The third sensor type measured skin head flux in the chest region and was not considered for further analysis in the current study. Download figure Open in new tab Figure 1: Textile monitoring system consisting of knitted electrodes (a) for ECG signal acquisition, a conductive stretch-sensitive textile (b) for the measurement of chest excursions, and a skin heat flux sensor (c; data not considered for further analysis in this study). The textile monitoring system was connected to a custom-made data logger (d) transferring data to a tablet (e) via Bluetooth. The 1-lead ECG system was previously clinically validated with 242 patients (Fontana, Martins et al. 2019). A similar combined system of ECG and respiratory monitoring was also used and validated for apnea monitoring and diagnostics (Baty, Cvetkovic et al. 2024). The data was recorded using a custom-made data logger placed in a pocket at the lower abdomen. Respiration was recorded at 25 Hz (Texas Instruments ADS131M08), while the ECG was recorded at 512 Hz (NeuroSky BMD101). Additionally, the logger was equipped with an Inertial Measurement Unit (IMU; Analog Devices ADXL345) to measure the acceleration in all spatial directions. To identify disturbances in signal quality motion artefacts, our group recently developed a method for signal quality assessment that was also applied in this present study ( 25 ). The method considers the entire PQRST complex of the ECG signal. The individual QRS and PQRST complexes are averaged for specific time segments of 15s. The similarity between each complex and the average value of the complexes (considered as reference complex for a specific time segment) is calculated using the Pearson correlation analysis. As a third parameter, the standard deviation of the RR-intervals in the measured segments is determined, and the number of outliers is assessed. We defined the plausibility of RR-intervals in a time segment to be true when the standard deviation of RR-intervals was between 1 and 200ms and no more than 2 outliers were detected (i.e. values corresponding to heart rates over 180 or under 30 beats per minute). This allowed a classification of the signal quality into 4 classes, considering the mean values of all Pearson correlation coefficients (PCC) in the ECG time segment and the plausibility criteria ( Table 1 ). Classes 1 and 2 were considered suitable for very accurate analyzes of the RR-intervals. View this table: View inline View popup Download powerpoint Table 1: Definition of the signal quality classes using the Pearson correlation coefficients (PCC) for the QRS and PQRST complexes of the ECG signal and the plausibility criteria for the RR intervals ( 25 ). Similarly, the median value of single chest excursion cycles for time segments of 30 seconds duration was calculated to assess the signal quality of respiration. The similarity of chest excursion cycles with the reference median value for a particular time segment was determined based on PCC. The signal was classified into three quality classes based on mean PCC values obtained for respiratory time segments: Class 1: PCC ≥ 0.85, Class 2: 0.75 < PCC < 0.85, and Class 3 ≤ 0.75. 2.2. Hypobaric hypoxia exposure The pilot aspirants underwent a standard training commonly practised at the Aeromedical Institute (FAI Dübendorf, Switzerland) in a low-pressure chamber, simulating an aviation scenario involving a loss of cabin pressure. The subjects participated in groups of two pilots in the exposure sessions, with a medical doctor closely supervising each session. Before the exposure, they underwent preoxygenation using aviation oxygen masks (AOM). Throughout the experiment, the AOM was intermittently removed for specific periods of the protocol ( Table 2 , Figure 2 ). During AOM-off periods, the participants were instructed to perform simple calculation tasks and respond to questions from the medical doctor to assess their cognitive performance. The numerical analysis of the data from the wearable system encompassed six distinct data intervals with an identical duration of 30 seconds each, denoted as i1 to i6 ( Figure 2 ). Data interval 1 (i1) captured the timeframe at the end of Phase 2 (ascend with AOM applied, Table 2 ). Phase 3 consists of the continuing ascent to 7500m asl and staying at this altitude without AOM. Data interval 2 (i2) includes data at the beginning of phase 3, while data interval 3 (i3) consists of data just before the AOM was reapplied (indicating the end of phase 3). Data interval 4 (i4) considers the time after the second removal of the AOM at an altitude of 9000m asl, and data interval 5 (i5) accounts for the 30 seconds just before the AOM was reapplied again at the end of Phase 5. Phases 3 and 5 consisted of hypoxic conditions. Download figure Open in new tab Figure 2: Simulated altitude profile. The blue periods highlight the phases when the participants had their aviator oxygen masks removed (phases 3 and 5). Details regarding the phases are available in Table 2 . The orange annotations (i1 to i6) indicate the specific 30-second measurement intervals for ECG and breathing signals. View this table: View inline View popup Download powerpoint Table 2: Hypobaric hypoxia exposition protocol. The altitude information refers to the altitude that corresponds to the air pressure in the chamber. 2.3. High-G exposures The participants underwent high-G exposures in a high-performance three-axis centrifuge at the Center for Aerospace Medicine in Königsbrück, Germany, to receive G-force qualification for military jet pilots. For this, pilot aspirants had to successfully complete a 7G exposure for 15s duration (according to NATO STANAG 3827). The 7G exposure was preceded by two exposures of 4G and 5.5G separated by baseline exposures of 1.4G with individual duration between 1 and 2min ( Figure 3 ). The numerical analysis of the data from the wearable system encompassed nine distinct data intervals (i1 – i9) with an identical duration of 15 seconds each, just before, during, and right after high-G exposures ( Figure 3 ). Download figure Open in new tab Figure 3 G-force exposure protocol for the qualification profile. The 15-second intervals i1 to i9 were used for the numeric analysis of the wearable system data (ECG and breathing signals). The orange annotations (i1 to i9) indicate the specific 30-second measurement intervals for ECG and breathing signals. 2.4. Statistical analysis A univariate repeated measures ANOVA with post hoc tests corrected according to Tukey was conducted for ECG (HR, HRV) and respiration-related parameters (fresp, ampresp). Data sets were checked for sphericity, homogeneity and normality. Corrections were applied for data sets not complying with sphericity requirements (Greenhouse-Geisser; data sets corrected are indicated in the text). The Jamovi software was used for statistical analysis ( 26 ). The level of significance was set at 0.05. 3. Results 3.1. Hypobaric hypoxia exposures The quality of the ECG signals obtained during the hypobaric hypoxia exposure of the participants was assessed and classified according to our signal quality assessment approach ( Table 1 ). A total of 91.7% of the ECG time segments were assigned to classes 1 to 3, indicating suitability for the further analysis of HR and HRV. The assessment of respiratory signals identified 71.9% of the respiratory time segments classified as class 1 or 2, which is required for the further analysis of respiratory signals ( Table 3 ). View this table: View inline View popup Download powerpoint Table 3: The mean ECG (ECG SQ) and respiratory signal quality (Resp SQ) and associated standard deviation (SD) for time segments assigned to classes 1 to 4 (ECG SQ) and classes 1 to 3 (Resp SQ) observed in 10 participants during hypobaric hypoxia exposure (see section 2.1 and Table 1 and for detailed assignment criteria). A statistically significant change in HR (repeated ANOVA, Greenhouse-Geisser corrected p<0.001) and HRV (repeated ANOVA, Greenhouse-Geisser corrected p<0.01) was detected ( Figure 5 ). No change in HR (+1%, p=0.98) was observed right after the initial removal of the AOM (i2), while HRV dropped by 22% (p=0.16). At the end of the first hypoxia exposure at 7500m asl (i3), both HR and HRV revealed significant changes by +34% (p<0.001) and -64% (p<0.01), respectively, when compared to i1. The second hypoxia exposure at 9000m asl resulted in a shorter exposure time (i5), while HR (+21%, p=0.07) and HRV (-44%, p=0.157) were not affected significantly when compared to i1, but a significant change was detected when compared to previous data interval i4 ( Figure 5 ). After the application of the AOM (i6), values returned immediately to preexposure data for HR (+2%, p=0.99) and HRV (+25%, p=0.84). Download figure Open in new tab Figure 5: Heart rate and heart rate variability for various measurement intervals (i1 – i6; further information on the prevailing conditions during the individual measurement intervals can be found in Figure 2 .) during hypobaric hypoxia exposure (ns: non-significant difference, *: p≤0.05, **: p≤ 0.01, ***: p≤0.001). Respiratory data did not reveal any statistically significant changes in respiratory frequency (repeated ANOVA p=0.06) nor respiratory sensor elongation amplitude (repeated ANOVA, Greenhouse-Geisser corrected p=0.24; Figure 6 ). Nevertheless, remarkable changes were observed right after the initial removal of the AOM (i2) for fresp (+18%) and ampresp (-15%) as well as at the end of the first hypoxia exposure at 7500m asl (i3; +26% and -10% for fresp and ampresp, respectively), when compared to i1. The second hypoxia exposure at 9000m asl (i5) revealed similar changes in fresp (+26%), while ampresp was affected more strongly (-20%), when compared to the first hypoxia exposure. After the application of the AOM (i6), values returned immediately to preexposure data for fresp (+0.3%) and showed increased ampresp (+22%). Download figure Open in new tab Figure 6: Respiratory frequency and respiratory sensor elongation amplitude for various measurement intervals (i1 – i6; further information on the prevailing conditions during the individual measurement intervals can be found in Figure 2 .) during hypobaric hypoxia exposure. High G-exposition Exemplary data is provided for the continuous monitoring of ECG signals and chest excursion ( Figure 7 ). The signal quality was impaired, particularly during the acceleration phases, with most of the signals in class 3 (indicated by the ECG curve colored in orange; Figure 7 , left). Download figure Open in new tab Figure 7: Exemplary data for ECG (a) and chest excursion signals (b) during high G-exposure qualification. The colouration of the ECG signal based on signal quality assigned to time windows of 15s duration: class 1 (dark green), class 2 (light green), class 3 (orange) and class 4 (red). In purple, the acceleration data from the Inertial Measurement Unit is presented. Chest excursion data obtained from respiratory sensor elongation (blue) and acceleration (orange). A quantified overview on how ECG time segments and respiratory time segments were attributed to the different quality classes is provided in Table 6 . A total of 82.8% of the ECG time segments and 76.0% of respiratory time segments were eligible for further analysis. View this table: View inline View popup Download powerpoint Table 6: The mean ECG (ECG SQ) and respiratory signal quality (Resp SQ) and associated standard deviation (SD) for time segments assigned to classes 1 to 4 (ECG SQ) and classes 1 to 3 (Resp SQ) observed in 10 participants during high-G exposition (see section 2.1 and Table 1 and for detailed assignment criteria). A significant change in HR was found during repeated exposures to high G-forces (repeated ANOVA, Greenhouse-Geisser corrected p<0.001), while no effect was observed for HRV (repeated ANOVA p=0.06). During high G-exposures, HR was significantly increased when compared to preceding values (19.5%, 17.5%, and 13.0% for 4G. 5.5G and 7G exposures, respectively ( Figure 8 ). A slight increase was also observed for resting HR at i4 (+4.3%, p=0.41) and i7 (+13.7%, p<0.05). For HRV, a high variation was observed particularly during and right after high G-exposure ( Figure 8 , right). Particularly during high G-exposure phases, a reduction in ECG signal quality was observed. Mean ECG time segment quality was increased for i2 (2.8±0.4), i5 (3.1±0.6) and i8 (3.5±0.7) when compared to average signal quality class during preceding data intervals (2.1 – 2.5). Download figure Open in new tab Figure 8: Heart rate and heart rate variability for various measurement intervals (i1 – i9; further information on the prevailing conditions during the individual measurement intervals can be found in section 2.3 , Figure 3 ) during high G-exposures (ns: non-significant difference, *: p≤0.05, **: p≤ 0.01, ***: p≤0.001). Even though a statistically significant effect was detected for fresp (repeated ANOVA p=0.007), no significant differences between subsequent data intervals were identified. A high coefficient of variation was particularly detected during measurement intervals right after high G-exposures (26.1%, 25.5%, and 22.6%, after 4G-, 5.5G-, and 7G-exposure, respectively), which might be attributed to a high average signal quality class for respiratory signals during respective measurement intervals (2.1±0.9, 1.7±0.7, and 1.9±0.7 for 4G-, 5.5G-, and 7G-exposure, respectively). In contrast, fresp variation was found to be much lower during high G-exposure measurement intervals with forced respiration (14.2%, 9.5%, and 3.8% during 4G-, 5.5G-, and 7G-exposure, respectively). Also, during these intervals, average signal quality classes were found to be improved when compared to above values (1.9±0.9, 1.3±0.8, and 1.9±1.1 for 4G-, 5.5G-, and 7G-exposure, respectively). 4. Discussion The textile monitoring system investigated achieved 91.7% and 82.2% of ECG time segments meeting the plausibility criteria (signal quality classes 1-3) during hypobaric hypoxia and high G-force exposure, respectively. For respiration, 71.9% and 76.0% of plausible respiratory time segments were identified during hypobaric hypoxia and high G-force exposure, respectively. In the low-pressure chamber, 82.3% of ECG time segments were classified as class 1 or 2, while this value was found to be 48.9% in the high-performance centrifuge only. Particularly during high G-exposures, heart rate variability was found to be increased even though a reduction in this variable would have been expected due to increased physical stress. We, therefore, assume that the ECG signal was affected by an increased muscular tension (mainly legs and torso), and the Valsalva manoeuvres resulted in increased muscular activity in the torso. This affected the electrophysiological recording of the ECG signal (i.e. superimposition of the ECG signal with increased electromyographic activity). Furthermore, the exposure to high accelerations in the centrifuge might also lead to motion artefacts. As a result, a reduction in signal quality was particularly observed during high G-exposure phases. In contrast, no increased muscular activity of legs and torso is expected during hypobaric hypoxia exposure (not measured in this study). Pilot aspirants were sitting in the low-pressure chamber without any accelerations. The calm body posture induced less noise and resulted in a higher data quality. Consequently, only 8% of the ECG time segments were classified in class 4 during hypoxia exposure and had to be discarded for further analysis. Despite the additional muscular activity and additional movement and force-related implications, only 18% of the ECG time segments monitored with our textile monitoring system had to be discarded for further analysis. The respiratory signals recorded with the same textile monitoring system did not reveal significant differences between the two training modalities for class 1 (48.5% ± 21.5% during hypoxia exposure and 47.1% ± 18.7% during high G-exposure) and class 2 (23.5% ± 9.0% and 28.8% ± 11.7% for hypoxia and high-G exposure, respectively). This was somewhat surprising as slightly reduced signal qualities were expected during high-G exposures due to movement artefacts and changes in respiratory patterns, particularly a reduction in respiratory amplitude ( Figure 9 ). This proves that the respiratory sensor measured chest excursions reliably, irrespective of increased muscular activity in the torso or motion artefacts. Download figure Open in new tab Figure 9: Respiratory frequency and respiratory sensor elongation amplitude for various measurement intervals (i1 – i9; further information on the prevailing conditions during the individual measurement intervals can be found in Figure 3 ) during high G-exposures (ns: non-significant difference, **: p≤ 0.01, ***: p≤0.001). Nevertheless, a high inter-participant variability was observed for the accuracy of data acquisition, resulting in standard deviations reaching 20%-30% for the ECG signal quality in both training modalities and around 10%- 20% for the respiratory signal quality. Thus, we assume individual factors, such as the fitting of the monitoring system and skin properties, affect the measurement quality and need to be considered as well. During the two high-altitude phases simulating 7500 and 9000 m without AOM, the heart rates increased significantly, accompanied by a significant drop in HRV, which is in line with findings from previous studies ( 6 ). For the respiratory patterns, the highest respiratory frequencies were found at the end of the hypoxia phases (i3 and i5); however, these changes did not reach statistical significance. Respiration immediately normalised after the application of the AOM, indicated by a reduction in respiratory frequency and an increase in respiratory amplitude. At the same time, an increase in HRV was also measured during interval 6, which shows that pilot aspirants were able to recover very quickly from the hypoxic stress with the administration of oxygen. As heart rate variability was immediately affected by hypoxic exposure and also heart rate revealed significant changes, it may be concluded that these parameters can be used to monitor the physiological stress induced by hypoxia, while respiratory patterns are not clear indicators. During the high-G exposures, significant differences in heart rate and respiratory amplitude were found. The changes in respiratory patterns were expected due to the breathing manoeuvres to maintain cerebral blood flow, which significantly reduced both the respiratory amplitude and slightly affected respiratory frequency as well. The increase in HR could be expected as well, as this was already demonstrated in several studies (e.g ( 27 ). The increase of HR was not related to the level of acceleration, as the mean value reached 154±9 bpm, 157±17 bpm and 152±11 bpm after 4G, 5.5G and 7G exposure, respectively. Peak HR was proposed as a possible predictor of G tolerance during training, as it was dependent on the age, the flying experience and the training status of the pilot aspirants ( 28 , 29 ). The increase in HRV might be observed due to the reduction in signal quality, as discussed above, or due to cardiac arrhythmias, which might have occurred during high- G exposure periods. Nevertheless, the results were found the be in the range reported in a recent study, which concluded that the significant change in HRV during a 5.5G exposure shows that this parameter may be used as a stress predictor and indicator for G-tolerance ( 30 ). 5. Conclusion The main goal of this study was to analyse the feasibility of using a textile-based sensor system for the monitoring of military pilots during different training modalities, such as hypobaric hypoxia, high-G exposure training or qualifications. The sensors were integrated into a textile belt that was worn around the chest. The ECG signals could be measured with a very good signal quality: over 90% of the ECG time segments allowed for further analysis of the signals during hypoxia training and over 80% during high-G-force training, which makes them suitable for very accurate analyses of the RR intervals. The recording of combined physiological data, such as ECG and respiratory signals, allows a more holistic interpretation of body responses when exposed to extreme and even hazardous environmental conditions. The effect of hypoxia could clearly be shown by immediate changes in heart rate variability and following changes in heart rate, while the respiratory patterns were less conclusive. During high G-force exposure, respiratory patterns revealed, such as a decrease in frequency and amplitude, in combination with changes in heart rate, provide objective information about the physical stress the pilot aspirant was exposed to. Peak heart rate as well as HRV can be used as indicators of the G-tolerance of the pilot aspirants. The applicability of such textile-based sensors for continuous monitoring of vital signs of military pilots during training was demonstrated. Further studies are planned with the inclusion of additional vital signs like oxygen saturation and body temperature. Such sensors can be potentially directly integrated into the pilot’s clothing. The collected data will be complemented with data from further studies and used to establish an algorithm for the early prediction of possible physical and cognitive impairments of pilots during training and on-duty flights. Data Availability Data cannot be shared publicly because the written consent for further use of data in encrypted form is not available for all the study participants. Data are available from the Institutional Data Access (contact via simon.annaheim{at}empa.ch ) for researchers who meet the criteria for access to confidential data. 6. Conflict of interest The authors state that they have no conflict of interest. Acknowledgements We sincerely thank all pilot aspirants for their valuable contribution to this study. Footnotes ↵ * shared last-author ship References 1. ↵ Physiologic Challenges to Pilots of Modern High Performance Aircraft . In: Aircraft Technology [Internet]. InTech ; 2018 [cited 2025 July 23]. p. 43 – 73 . Available from: http://www.intechopen.com/books/aircraft-technology/physiologic-challenges-to-pilots-of-modern-high-performance-aircraft 2. ↵ Romer LM , Haverkamp HC , Amann M , Lovering AT , Pegelow DF , Dempsey JA . Effect of acute severe hypoxia on peripheral fatigue and endurance capacity in healthy humans . Am J Physiol-Regul Integr Comp Physiol . 2007 Jan ; 292 ( 1 ): R598 – 606 . OpenUrl 3. ↵ Truszczyński O , Wojtkowiak M , Biernacki M , Kowalczuk K . The effect of hypoxia on the critical flicker fusion threshold in pilots . Int J Occup Med Environ Health [Internet ]. 2009 Jan 1 [cited 2025 July 23]; 22 ( 1 ). Available from: http://www.imp.lodz.pl/home_en/publishing_office/journals_/_ijomeh/&arti-cleId=21062&l=EN 4. ↵ Vigo DE , Pérez Lloret S , Videla AJ , Pérez Chada D , Hünicken HM , Mercuri J , et al. Heart Rate Nonlinear Dynamics During Sudden Hypoxia at 8230 m Simulated Altitude . Wilderness Environ Med . 2010 Mar ; 21 ( 1 ): 4 – 10 . OpenUrl PubMed 5. ↵ Verges S , Bachasson D , Wuyam B . Effect of acute hypoxia on respiratory muscle fatigue in healthy humans . Respir Res [Internet ]. 2010 Dec [cited 2025 July 23];11(1). Available from: http://respiratory-research.biomedcentral.com/articles/10.1186/1465-9921-11-109 6. ↵ Bustamante-Sánchez A , Gil-Cabrera J , Tornero-Aguilera JF , Fernandez-Lucas J , Ramos-Campo DJ , Clemente-Suárez VJ . Effects of Hypoxia on Selected Psychophysiological Stress Responses of Military Aircrew . Yousaf MS , editor. BioMed Res Int [Internet]. 2021 Jan [cited 2025 July 23]; 2021 ( 1 ). Available from: https://onlinelibrary.wiley.com/doi/10.1155/2021/6633851 7. ↵ McMorris T , Hale BJ , Barwood M , Costello J , Corbett J . Effect of acute hypoxia on cognition: A systematic review and meta-regression analysis . Neurosci Biobehav Rev . 2017 Mar ; 74 : 225 – 32 . OpenUrl CrossRef PubMed 8. ↵ Choi B , Kim D , Kim M , Hwang S . Effectiveness of EMG in Development of G-induced Loss of Consciousness (G-LOC) Warning System . In: Proceedings of the International Conference on Biomedical Engineering and Systems . Prague , Czech Republic ; August 14-15. p. Paper No. 129. 9. ↵ Slungaard E , McLeod J , Green NDC , Kiran A , Newham DJ , Harridge SDR . Incidence of G-Induced Loss of Consciousness and Almost Loss of Consciousness in the Royal Air Force . Aerosp Med Hum Perform . 2017 June 1; 88 ( 6 ): 550 – 5 . OpenUrl PubMed 10. ↵ Kim S , Choi B , Cho T , Lee Y , Koo H , Kim D . Wearable bio signal monitoring system applied to aviation safety . In: 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) [Internet] . Seogwipo : IEEE ; 2017 [cited 2025 July 23]. p. 2349 – 52 . Available from: https://ieeexplore.ieee.org/document/8037327/ 11. ↵ Kutilek P , Kacer J , Cicmanec L , Volf P , Hejda J , Smrcka P , et al. Non-contact Measurement Systems for Physiological Data Monitoring of Military Pilots During Training on Simulators: Review and Application . I n: 2019 International Conference on Military Technologies (ICMT) [Internet] . Brno, Czech Republic : IEEE ; 2019 [cited 2025 July 23]. p. 1 – 6 . Available from: https://ieeexplore.ieee.org/document/8870115/ 12. ↵ Xing G , Sun Y , He F , Wei P , Wu S , Ren H , et al. Analysis of Human Factors in Typical Accident Tests of Certain Type Flight Simulator . Sustainability . 2023 Feb 3; 15 ( 3 ): 2791 . OpenUrl 13. ↵ Scannella S , Peysakhovich V , Ehrig F , Lepron E , Dehais F . Assessment of Ocular and Physiological Metrics to Discriminate Flight Phases in Real Light Aircraft . Hum Factors J Hum Factors Ergon Soc . 2018 Nov ; 60 ( 7 ): 922 – 35 . OpenUrl 14. ↵ Kim C , Koh G . Integrated Flight Safety System to Cope with Gravity-Induced Loss of Consciousness—Industrial Perspective . Int J Aeronaut Space Sci . 2025 Apr ; 26 ( 3 ): 1363 – 85 . OpenUrl 15. ↵ Yang J , Tang M , Cong L , Sun J , Guo D , Zhang T , et al. Development and validation of an assessment index for quantifying cognitive task load in pilots under simulated flight conditions using heart rate variability and principal component analysis . Ergonomics . 2024 Apr 2; 67 ( 4 ): 515 – 25 . OpenUrl PubMed 16. ↵ Coffey A , Marston P , Pollock R , Harrison R , Diwan S , Ravisankar S , et al. An Investigation into the Validity of Sports Wearables for Heart Rate Monitoring in General . Aerosp Med Hum Perform . 2024 ; 95 ( 8 ): 466 . OpenUrl 17. ↵ De Vries HJ , Van Der Wal SJ , Delahaij R , Venrooij W , Kamphuis W . Real-time monitoring of military health and readiness: a perspective on future research . Front Digit Health [Internet]. 2025 May 7 [cited 2025 July 23]; 7 . Available from: https://www.frontiersin.org/articles/10.3389/fdgth.2025.1542140/full 18. ↵ An Aircraft Pilot Workload Sensing System . In: Lecture Notes in Civil Engineering [Internet]. Cham : Springer International Publishing ; 2021 [cited 2025 July 23]. p. 883 – 92 . Available from: http://link.springer.com/10.1007/978-3-030-64594-6_85 19. ↵ Chen J , Xue L , Rong J , Gao X . Real-time evaluation method of flight mission load based on sensitivity analysis of physiological factors . Chin J Aeronaut . 2022 Mar ; 35 ( 3 ): 450 – 63 . OpenUrl 20. ↵ Kelly N , Gilbert SB . The Wearer, the Device, and Its Use: Advances in Understanding the Social Acceptability of Wearables . Proc Hum Factors Ergon Soc Annu Meet . 2018 Sept; 62 ( 1 ): 1027 – 31 . OpenUrl 21. ↵ Li S , Li H , Lu Y , Zhou M , Jiang S , Du X , et al. Advanced Textile-Based Wearable Biosensors for Healthcare Monitoring . Biosensors . 2023 Sept 27; 13 ( 10 ): 909 . OpenUrl PubMed 22. ↵ An X , K. Stylios G . Comparison of Motion Artefact Reduction Methods and the Implementation of Adaptive Motion Artefact Reduction in Wearable Electrocardiogram Monitoring . Sensors . 2020 Mar 7; 20 ( 5 ): 1468 . OpenUrl PubMed 23. ↵ Baty F , Cvetkovic D , Boesch M , Bauer F , Adão Martins NR , Rossi RM , et al. Validation of a Textile-Based Wearable Measuring Electrocardiogram and Breathing Frequency for Sleep Apnea Monitoring . Sensors . 2024 Sept 26; 24 ( 19 ): 6229 . OpenUrl PubMed 24. ↵ World Medical Association . World Medical Association Declaration of Helsinki: Ethical Principles for Medical Research Involving Human Participants . JAMA . 2025 Jan 7; 333 ( 1 ): 71 . OpenUrl PubMed 25. ↵ Martins NA , Bauer F , Baty F , Boesch M , Brutsche M , Rossi R , et al. Introduction to electrocardiogram signal quality assessment and estimated accuracy for textile electrodes [Internet] . Springer Science and Business Media LLC ; 2025 [cited 2025 July 23]. Available from: https://www.researchsquare.com/article/rs-5804513/v1 26. ↵ The jamovi project [Internet]. 2024 . Available from: https://www.jamovi.org/ 27. ↵ Metin S , Senol L , Gunduz SH , Avci AU , Yasar S . Evaluation of Cardiac Autonomic Activity During + Gz Stress in Military Pilots . Microgravity Sci Technol [Internet ]. 2023 Jan 3 [cited 2025 July 23]; 35 ( 1 ). Available from: https://link.springer.com/10.1007/s12217-022-10028-7 28. ↵ Tu MY , Chu H , Lin YJ , Chiang KT , Chen CM , Chen HH , et al. Combined effect of heart rate responses and the anti-G straining manoeuvre effectiveness on G tolerance in a human centrifuge . Sci Rep [Internet ]. 2020 Dec 10 [cited 2025 July 23]; 10 ( 1 ). Available from: https://www.nature.com/articles/s41598-020-78687-3 29. ↵ Kumar A . Effect of age and flying experience on heart rate response of fighter aircrew during high-G exposure in the high-performance human centrifuge . Indian J Aerosp Med . 2023 Nov 22; 67 : 2 – 7 . OpenUrl 30. ↵ Bacevic N , Ninkovic M , Drvendzija M , Vidakovic J , Bacevic M , Stepanic P . Heart Rate Variability as a Predictor of +Gz Tolerance During the High-G Selective Test . Aerosp Med Hum Perform . 2024 Feb ; 95 ( 2 ): 93 – 100 . OpenUrl PubMed View the discussion thread. Back to top Previous Next Posted September 05, 2025. Download PDF Data/Code Email Thank you for your interest in spreading the word about medRxiv. NOTE: Your email address is requested solely to identify you as the sender of this article. Your Email * Your Name * Send To * Enter multiple addresses on separate lines or separate them with commas. You are going to email the following Monitoring Military Pilots with Textile Sensors: Physiological Responses and Signal Quality Under Extreme Conditions Message Subject (Your Name) has forwarded a page to you from medRxiv Message Body (Your Name) thought you would like to see this page from the medRxiv website. Your Personal Message CAPTCHA This question is for testing whether or not you are a human visitor and to prevent automated spam submissions. Share Monitoring Military Pilots with Textile Sensors: Physiological Responses and Signal Quality Under Extreme Conditions René M. Rossi , Frederik Bauer , Andreas Stier , Dennis Bron , Simon Annaheim medRxiv 2025.09.03.25332904; doi: https://doi.org/10.1101/2025.09.03.25332904 Share This Article: Copy Citation Tools Monitoring Military Pilots with Textile Sensors: Physiological Responses and Signal Quality Under Extreme Conditions René M. Rossi , Frederik Bauer , Andreas Stier , Dennis Bron , Simon Annaheim medRxiv 2025.09.03.25332904; doi: https://doi.org/10.1101/2025.09.03.25332904 Citation Manager Formats BibTeX Bookends EasyBib EndNote (tagged) EndNote 8 (xml) Medlars Mendeley Papers RefWorks Tagged Ref Manager RIS Zotero Tweet Widget Facebook Like Google Plus One Subject Area Occupational and Environmental Health Subject Areas All Articles Addiction Medicine (567) Allergy and Immunology (863) Anesthesia (297) Cardiovascular Medicine (4411) Dentistry and Oral Medicine (443) Dermatology (380) Emergency Medicine (606) Endocrinology (including Diabetes Mellitus and Metabolic Disease) (1505) Epidemiology (15205) Forensic Medicine (30) Gastroenterology (1119) Genetic and Genomic Medicine (6574) Geriatric Medicine (666) Health Economics (994) Health Informatics (4511) Health Policy (1365) Health Systems and Quality Improvement (1608) Hematology (537) HIV/AIDS (1263) Infectious Diseases (except HIV/AIDS) (15903) Intensive Care and Critical Care Medicine (1103) Medical Education (620) Medical Ethics (144) Nephrology (665) Neurology (6573) Nursing (345) Nutrition (998) Obstetrics and Gynecology (1139) Occupational and Environmental Health (954) Oncology (3319) Ophthalmology (967) Orthopedics (369) Otolaryngology (420) Pain Medicine (435) Palliative Medicine (129) Pathology (662) Pediatrics (1689) Pharmacology and Therapeutics (691) Primary Care Research (710) Psychiatry and Clinical Psychology (5421) Public and Global Health (9205) Radiology and Imaging (2191) Rehabilitation Medicine and Physical Therapy (1367) Respiratory Medicine (1191) Rheumatology (593) Sexual and Reproductive Health (709) Sports Medicine (529) Surgery (709) Toxicology (99) Transplantation (288) Urology (265) (function(){function c(){var b=a.contentDocument||a.contentWindow.document;if(b){var d=b.createElement('script');d.innerHTML="window.__CF$cv$params={r:'9fe8ce445c144193',t:'MTc3OTI1MzUyMA=='};var a=document.createElement('script');a.src='/cdn-cgi/challenge-platform/scripts/jsd/main.js';document.getElementsByTagName('head')[0].appendChild(a);";b.getElementsByTagName('head')[0].appendChild(d)}}if(document.body){var a=document.createElement('iframe');a.height=1;a.width=1;a.style.position='absolute';a.style.top=0;a.style.left=0;a.style.border='none';a.style.visibility='hidden';document.body.appendChild(a);if('loading'!==document.readyState)c();else if(window.addEventListener)document.addEventListener('DOMContentLoaded',c);else{var e=document.onreadystatechange||function(){};document.onreadystatechange=function(b){e(b);'loading'!==document.readyState&&(document.onreadystatechange=e,c())}}}})();

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: preprint-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-05-22T02:00:06.705733+00:00
License: CC-BY-NC-ND-4.0