Mechanistic insights into heterogeneous radiofrequency ablation effects at the left atrial posterior wall during pulmonary vein isolation
preprint
OA: closed
CC-BY-NC-4.0
AI-generated summary
This study investigated radiofrequency ablation heterogeneity at the left atrial posterior wall during pulmonary vein isolation, finding greater ablation effects on the left side potentially due to increased contact surface area and in-phase catheter-tissue motion.
One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works
Abstract
Background Independent investigations demonstrate greater radiofrequency (RF) ablation effects at left- sided left atrial posterior wall (LAPW) sites. Objective To investigate mechanisms underlying RF ablation heterogeneity during contact-force (CF) and VISITAG™ Module (Biosense Webster)-guided pulmonary vein isolation (PVI). Methods Consecutive patients undergoing PVI during atrial overdrive pacing comprised 2 cohorts: intermittent positive pressure ventilation (IPPV, 14-16/min, 6-8ml/kg); high frequency jet ventilation (HFJV, 150/min, Monsoon III, Acutronic). Temperature-controlled (17ml/min, 48°C) RF data was retrospectively assessed at first-annotated (target 15s) LAPW sites: 30W during IPPV; 20W at left-sided sites during HFJV. Results Twenty-five and 15 patients underwent PVI during IPPV and HFJV, respectively. During IPPV, left versus right-sided median impedance drop (ImpD) was 13.6Ω versus 9.9Ω (p<0.0001) respectively and mean time to pure R unipolar electrogram (UE) morphology change 4.9s versus 6.7s (p=0.007) respectively. During HFJV, ImpD was greater at left-sided sites (9.7Ω versus 7.4Ω, p=0.21) and time to pure R UE significantly shorter: 4.3s versus 6.1s (p=0.02). Minimum case impedance subtracted from pre-RF baseline impedance (BI) generated site-specific ΔBI. Left-sided sites demonstrated significantly greater ΔBI, correlating strongly with Ln(ImpD) – IPPV r=0.84 (0.65 – 0.93), HFJV r=0.77 (0.35 – 0.93). At right-sided sites, ΔBI and Ln(ImpD) were without correlation during IPPV, but correlation was modest during HFJV (r=0.54, -0.007 – 0.84). Conclusions ΔBI may usefully indicate catheter-tissue contact surface area (SA). Consequently, greater left-sided LAPW RF effect may result from greater contact SA and in-phase catheter-tissue motion; HFJV may reduce right-sided out-of-phase catheter-tissue motion. Modifying RF delivery based on ΔBI may improve PVI safety and efficacy.
My notes (saved in your browser only)
Citation neighborhood (sparse)
Too few in-corpus citations on either side for a chart; here are the lists.
Cites (1)
References (23)
- Ablation catheter motion detection during contact force and VISITAG™ Module-guided pulmonary vein isolation via crossref
- doi:10.1016/j.jacc.2011.09.076 via crossref
- doi:10.1161/circep.118.006576 via crossref
- doi:10.1016/j.jacep.2017.06.023 via crossref
- doi:10.1016/j.hrthm.2019.01.030 via crossref
- doi:10.1007/s10840-015-0002-8 via crossref
- doi:10.1111/jce.13426 via crossref
- doi:10.1111/pace.13729 via crossref
- doi:10.1016/j.hrthm.2010.06.014 via crossref
- doi:10.1161/circep.115.002894 via crossref
- doi:10.1111/j.1540-8159.2006.00533.x via crossref
- doi:10.1016/s0002-8703(98)70130-9 via crossref
- doi:10.1023/a:1026586119600 via crossref
- doi:10.1093/europace/eur046 via crossref
- doi:10.1111/jce.12386 via crossref
- doi:10.1161/circep.113.000749 via crossref
- doi:10.1161/circep.119.007304 via crossref
- doi:10.1016/j.jacep.2018.07.017 via crossref
- doi:10.1016/j.jacep.2019.04.009 via crossref
- doi:10.1111/jce.13363 via crossref
- doi:10.1161/01.cir.98.5.458 via crossref
- doi:10.1016/j.hrthm.2017.05.012 via crossref
- doi:10.1111/jce.13386 via crossref
Source provenance
- crossref
- last seen: 2026-06-06T01:00:25.846418+00:00
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00
- unpaywall
- last seen: 2026-05-22T02:00:06.705733+00:00
License: CC-BY-NC-4.0