SEKI, Ryosuke

ORCID: 0000-0002-5364-805X · 205 papers in corpus · active 2024-2025

Study types

  • dataset 205
dataset 2025
·doi:10.57451/lhd.ctsfosc1.171957.1

A collective Thomson scattering (CTS) diagnostic with a ±3 GHz band around a 77 GHz gyrotron probe beam is to measure the velocity distribution of bulk and fast ions in high-temperature plasmas.

dataset 2025
·doi:10.57451/lhd.ctsfosc1.194921.1

A collective Thomson scattering (CTS) diagnostic with a ±3 GHz band around a 77 GHz gyrotron probe beam is to measure the velocity distribution of bulk and fast ions in high-temperature plasmas.

dataset 2025
·doi:10.57451/lhd.ctsfosc2.194700.1

A collective Thomson scattering (CTS) diagnostic with a ±3 GHz band around a 77 GHz gyrotron probe beam is to measure the velocity distribution of bulk and fast ions in high-temperature plasmas.

dataset 2025
·doi:10.57451/lhd.eb-npa.115454.1

To study fast ion confinement and transport mechanisms both in quiescent plasmas and in the presence of magneto-hydrodynamic (MHD) activity, an electric field parallel to the magnetic field type neutral particle analyzer (E||B-NPA) was inst…

dataset 2025
·doi:10.57451/lhd.eb-npa-c.159972.1

To study fast ion confinement and transport mechanisms both in quiescent plasmas and in the presence of magneto-hydrodynamic (MHD) activity, an electric field parallel to the magnetic field type neutral particle analyzer (E||B-NPA) was inst…

dataset 2025
·doi:10.57451/lhd.gamma.178565.1

Charge exchanged fast neutral measurement in LHD for understanding energetic ion confinement

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.113555.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.115606.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.117788.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.118790.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.119155.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.122877.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.126861.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.132306.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.138194.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.141833.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.143654.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.144261.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.145938.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.148682.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.149282.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.153674.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.156221.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.156658.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.

dataset 2025
·doi:10.57451/lhd.a.lhdgauss_input.161623.1

Electron cyclotron heating (ECH) injection settings determined by the ECH setting log generated for each shot.