A Biomechanical Hand Model to Quantify Finger Joint Kinematics Using a 3D Motion Capture System
preprint
OA: closed
Abstract
The kinematics of rhythmic, speed-modulated finger and grasp-like movements were analyzed using a reduced biomechanical model of the hand and a marker-based optical motion-capture system. Twenty-one healthy participants performed eight hand motor tasks involving metacarpophalangeal (MCP) joint flexion–extension (F–E) and carpometacarpal (CMC) thumb opposition–reposition (O–R) at two movement frequencies (0.50 and 0.75 Hz). Kinematic analysis quantified the range of movement (RoM), mean speed, and normalized total harmonic distortion (TDH N ). Statistical analysis identified task type as the primary factor modulating all three metrics across digits, with large effect sizes . Movement frequency significantly influenced mean speed and moderately affected TDH N , while thumb RoM remained statistically unchanged across frequencies ( p = 0.063). Participants consistently reproduced the intended sinusoidal trajectories, as indicated by low TDH N values (below 19%). The findings support the analysis of coordinated hand movements across various tasks under controlled time conditions. They also demonstrate that the simplified biomechanical model accurately captured both individual and co-ordinated finger movements. This provides a valuable reference for studies on motor control and for applications in rehabilitation and assistive technology.
Full text
1,435 characters
· extracted from
oa-doi-fallback
· click to expand
Abstract
The kinematics of rhythmic, speed-modulated finger and grasp-like movements were analyzed using a reduced biomechanical model of the hand and a marker-based optical motion-capture system. Twenty-one healthy participants performed eight hand motor tasks involving metacarpophalangeal (MCP) joint flexion–extension (F–E) and carpometacarpal (CMC) thumb opposition–reposition (O–R) at two movement frequencies (0.50 and 0.75 Hz). Kinematic analysis quantified the range of movement (RoM), mean speed, and normalized total harmonic distortion (TDHN). Statistical analysis identified task type as the primary factor modulating all three metrics across digits, with large effect sizes . Movement frequency significantly influenced mean speed and moderately affected TDHN , while thumb RoM remained statistically unchanged across frequencies (p = 0.063). Participants consistently reproduced the intended sinusoidal trajectories, as indicated by low TDHN values (below 19%). The findings support the analysis of coordinated hand movements across various tasks under controlled time conditions. They also demonstrate that the simplified biomechanical model accurately captured both individual and co-ordinated finger movements. This provides a valuable reference for studies on motor control and for applications in rehabilitation and assistive technology.
Competing Interest Statement
The authors have declared no competing interest.
Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.
My notes (saved in your browser only)
Ask this paper
Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works
Funding
- funders
- [{'doi': None, 'name': 'Brazilian Public Ministry of Labor', 'awards': ['002118.2019']}, {'doi': '10.13039/501100002322', 'name': 'CAPES', 'awards': ['88887.842775/2023-00']}, {'doi': '10.13039/501100001807', 'name': 'FAPESP', 'awards': ['2020/13293-0']}]
Citation neighborhood (sparse)
Too few in-corpus citations on either side for a chart; here are the lists.
Cites (1)
References (49)
- A Wearable Platform for Real-Time Control of a Prosthetic Hand by High-Density EMG via crossref
- doi:10.1177/1753193414533754 via crossref
- doi:10.1007/s11552-013-9492-y via crossref
- doi:10.1038/s41551-020-00630-8 via crossref
- doi:10.1016/j.jbiomech.2017.06.026 via crossref
- doi:10.1055/s-0044-1788593 via crossref
- doi:10.1109/tnsre.2020.2967901 via crossref
- doi:10.3390/bioengineering10020219 via crossref
- doi:10.1016/j.jelekin.2010.07.004 via crossref
- doi:10.1177/001316447303300111 via crossref
- doi:10.1016/j.jbiomech.2025.112590 via crossref
- doi:10.1162/jocn_a_02268 via crossref
- doi:10.3390/app15031296 via crossref
- doi:10.3390/technologies13050169 via crossref
- doi:10.3390/app15115842 via crossref
- doi:10.1177/1753193412444399 via crossref
- doi:10.3389/fpsyg.2020.574396 via crossref
- doi:10.1523/jneurosci.20-22-08542.2000 via crossref
- doi:10.1523/jneurosci.20-22-08542.2000 via crossref
- doi:10.1177/1729881419862164 via crossref
- doi:10.1055/b-0036-140288 via crossref
- doi:10.1109/tnsre.2020.2998642 via crossref
- doi:10.1016/j.humov.2007.08.005 via crossref
- doi:10.1152/japplphysiol.00606.2023 via crossref
- doi:10.3390/biomimetics8020244 via crossref
- doi:10.3390/machines11100964 via crossref
- doi:10.1186/s12984-015-0040-6 via crossref
- doi:10.1109/tbme.2022.3217722 via crossref
- doi:10.1002/aisy.202200189 via crossref
- doi:10.1371/journal.pcbi.1009597 via crossref
- doi:10.1016/j.jbiomech.2018.02.010 via crossref
- doi:10.1038/s41467-024-50101-w via crossref
- doi:10.3390/electronics12030625 via crossref
- doi:10.1016/j.bbe.2025.07.004 via crossref
- doi:10.1186/s13018-019-1177-y via crossref
- doi:10.1162/jocn_a_01763 via crossref
- doi:10.1152/jn.00712.2015 via crossref
- doi:10.1007/s00221-011-2872-z via crossref
- doi:10.7305/automatika.54-1.300 via crossref
- doi:10.1109/tpwrd.2004.839744 via crossref
- doi:10.1038/s41583-021-00528-7 via crossref
- doi:10.1007/978-3-032-04688-8_7 via crossref
- doi:10.1109/tau.1967.1161901 via crossref
- doi:10.1016/0141-1195(86)90098-7 via crossref
- doi:10.1155/2022/1953861 via crossref
- doi:10.3389/fbioe.2025.1702269 via crossref
- doi:10.1007/978-3-031-32198-6_2 via crossref
- doi:10.6084/m9.figshare.31032934 via crossref
- doi:10.3389/fnbot.2021.734525 via crossref
Source provenance
- crossref
- last seen: 2026-06-03T07:24:01.438061+00:00
- europepmc
- last seen: 2026-05-20T01:45:00.602351+00:00
- unpaywall
- last seen: 2026-08-08T06:39:30.753600+00:00